3. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flames and oven burner
flames is very important. The small inner cone should have a
very distinct blue flame ¼" (0.6 cm) to ½" (1.3 cm) long. The
outer cone is not as distinct as the inner cone. LP gas flames
have a slightly yellow tip.
IMPORTANT: You may have to adjust the “LO” setting for
each cooktop burner.
Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the “closed” position.
2. Unplug range or disconnect power.
B
A
C
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
3. Remove warming drawer or storage drawer. See the
“Remove Warming or Storage Drawer” section for
instructions. Locate gas pressure regulator at rear of storage
or warming drawer compartment.
NOTE: On models with a warming drawer, an access cover
must be removed from the gas pressure regulator.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Page 18