Electrical Requirements - KitchenAid KBZU122TSS Installation Instructions And Use & Care Manual

Outdoor built-in dual side burners
Table of Contents

Advertisement

Available languages

Available languages

Warming Drawer Size
24" (61.0 cm)
*Dimension L is the minimum mounting surface area around the opening for mounting the optional door or drawers.
Built-in Outdoor Grill Enclosure Ventilation for LP Gas:
An enclosure for an LP gas fuel tank is to be ventilated by
openings at both the top and lower levels of the enclosure.
If converting to LP gas these vents are to be in the enclosure:
An enclosure for use with an LP gas fuel tank for built-in
installation is to have at least one ventilation opening on an
exposed exterior side located within 5" (12.7 cm) of the top is to
be a minimum of 20 in.
2
(129.0 cm
within 1" (2.5 cm) of the bottom of the enclosure and the bottom
opening is to be a minimum of 10 in.
openings are to be unobstructed. Every opening is to be a
minimum of
" (0.32 cm) wide.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are not sure whether the
side burner is properly grounded.
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is
required.
It is recommended that a separate circuit servicing only this side
burner be provided.
To avoid electrical shock, do not immerse cord or plugs in
water or other liquid.
Unplug from the outlet when not in use and before
cleaning. Allow to cool before putting on or taking off
parts.
Cutout Dimensions - Built-in Warming Drawer
Dimension J
22½" (57.2 cm)
Cutout Dimensions - Built-in Utility Drawer and Built-in Trash Drawer
Dimension M
12¼" (31.1 cm)
2
). One ventilation opening
2
(64.5 cm
2
). All vent

Electrical Requirements

Dimension L*
1½" (3.8 cm)
2
2
20 in.
(129.0 cm
) min.
ventilation both sides
1" (2.5 cm) max.
2
2
10 in.
(64.5 cm
) min.
ventilation both sides
Do not operate any outdoor cooking gas appliance with a
damaged cord, damaged plug, or after the appliance
malfunctions or has been damaged in any manner.
Contact the manufacturer for repair.
Do not let the cord hang over the edge of a table or touch
hot surfaces.
Do not use an outdoor cooking appliance for purposes
other than intended.
When connecting, first connect plug to the outdoor
cooking gas appliance then plug appliance into the outlet.
Use only a Ground Fault Interrupter (GFI) protected circuit
with this outdoor cooking gas appliance.
Do not remove the ground prong or use with an adapter
of 2 prongs.
The model/serial number rating plate is located on the right-hand
side panel. See the following illustration.
A
A. Model/serial number plate
5" (12.7 cm) max.
5" (12.7 cm) max.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbzu122vssKbzu242vssW10176789aKbzu242tss

Table of Contents