Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Dyna-Glo
Gas Radiant Heaters
Description
Dyna-Glo Delux Models RA100NGDGD and RA250NGDGD heaters are 50,000 to
100,000 and 250,000 BTU/Hr construction heaters. These heaters use natural gas for
combustion. They are primarily intended for temporary heating of well-ventilated
buildings under construction, alteration or repair. These heaters should be utilized
in sheltered, well-ventilated areas, but never in occupied dwellings.
ANS Z83.7b-2009 CSA 2.14b-2009 Construction Heater

Specifications

Fuel Consumption
Model
BTU/Hr
Maximum
RA100NGDGD 50,000 to 5.1 lbs
100,000
RA250NGDGD 250,000
12.8 lbs
Fuel Type – Natural Gas Only
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make sure you read and thoroughly
understand these safety and operating
instructions. Keep these instructions for
future reference. They are your guides
to safe and proper operation of this
heater.
Delux Natural
®
C
US
Min. Gas
Max. Gas
Supply Pressure Supply Pressure Pressure Gap
8" W.C.
14" W.C.
10 PSI
250 PSI
Ignition Type – Piezo (RA100NGDGD)
Pilot (RA250NGDGD)
Safety information appears throughout
this manual. Pay close attention to
them. Below are definitions for the
safety information listed throughout
this manual.
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
situation which, if not avoided, COULD
result in death or serious injury.
situa tion which, if not avoided, MAY
result in minor or moderate injury.
vehicle use.
Printed in China
RA100NGDGD and RA250NGDGD
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714
Figure 1 – Models RA100NGDGD / RA250NGDGD
Manifold Ignitor
7.5" W.C. 0.19"
6 PSI
0.19"
Minimum Operating Temp. – -20°F (-29°C)
WarninG: Failure to comply with the
precautions and instructions provided
with this heater can result in death,
serious bodily injury, and property loss,
Indicates an
or damage from hazards of fire,
im minen tly
explosion, burn, asphyxiation, carbon
monoxide poisoning, and/or electrical
shock. Only persons who can
understand and follow these
instructions should use or service this
Indicates a poten­
heater. If you need assistance or heater
tially hazardous
information such as an instruction
manual, labels, etc., contact your local
manufacturer.
Indicates a poten­
tially hazardous
Consumer: Retain this manual for
future reference.
Not for home
or recreational
Rev. 2013-06-13
Size
Weight (Lbs) L x W x H (in.)
18.7 (heater)
16.3 x 16.3 x 29.8
30.8 (heater)
14.7 x 14.7 x 44.3
General
Hazard
PROFESSIONAL GRADE
E
N
G
L
I
S
H
E
S
P
A
O
L
F
R
A
N
Ç
A
I
S

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo RA100NGDGD

  • Page 1: Specifications

    ® Gas Radiant Heaters Description Dyna-Glo Delux Models RA100NGDGD and RA250NGDGD heaters are 50,000 to 100,000 and 250,000 BTU/Hr construction heaters. These heaters use natural gas for combustion. They are primarily intended for temporary heating of well-ventilated buildings under construction, alteration or repair. These heaters should be utilized in sheltered, well-ventilated areas, but never in occupied dwellings.
  • Page 2: General Safety Information

    RA100NGDGD and RA250NGDGD Dyna-Glo Delux Operating Instructions and Parts Manual Dyna-Glo Delux Natural Gas ® Radiant Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! General Safety Information IMPORTANT: Every possible chemicals known to the State of circumstance that might involve a...
  • Page 3 Dyna-Glo Delux Operating Instructions and Parts Manual Models RA100NGDGD and RA250NGDGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! General Safety Information – Do not use heater if altered. (Continued) – Turn off gas supply to heater when not in use.
  • Page 4: Operation

    RA100NGDGD and RA250NGDGD Dyna-Glo Delux Operating Instructions and Parts Manual Dyna-Glo Delux Natural Gas ® Radiant Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Operation 2. Always be sure to place the heater on TO SHUT DOWN HEATER a stable and level surface while the Hot while in 1.
  • Page 5: Natural Gas Supply

    Dyna-Glo Delux Operating Instructions and Parts Manual Models RA100NGDGD and RA250NGDGD NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Operation (Continued) Check with your local gas supplier to Running heater below specified gas properly size all of your supply lines. Be NOTE: Arrows on main burner valve pressure may cause flashback.
  • Page 6: Maintenance

    RA100NGDGD and RA250NGDGD Dyna-Glo Delux Operating Instructions and Parts Manual Dyna-Glo Delux Natural Gas ® Radiant Heaters NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Maintenance STORAGE 3. Inspect regulator hose assembly before each use. If hose is highly Disconnect heater...
  • Page 7 For repair Parts, call 1-877-447-4768 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Figure 6 – Repair Parts Illustration for Natural Gas Radiant Heater RA100NGDGD...
  • Page 8 Heater must use design­specific parts. Do not substitute or use generic parts. Improper NEVER LEAVE THE HEATER replacement parts could cause serious or fatal injuries. UNATTENDED WHILE BURNING! Repair Parts List for Natural Gas Radiant Heater RA100NGDGD Reference Part Number for Model: Number Description RA100NGDGD...
  • Page 9 RA250NGDGD Dyna-Glo Delux Operating Instructions and Parts Manual For repair Parts, call 1-877-447-4768 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Figure 7 – Repair Parts Illustration for Natural Gas Radiant Heater RA250NGDGD For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:00 am - 5:00 pm CST www.ghpgroupinc.com...
  • Page 10 Dyna-Glo Delux Operating Instructions and Parts Manual Model RA250NGDGD Use only original WARNING replacement parts. This Heater must use design­specific parts. Do not substitute or use generic parts. Improper NEVER LEAVE THE HEATER replacement parts could cause serious or fatal injuries.
  • Page 11 Warranty RA100NGDGD and RA250NGDGD Dyna-Glo Delux Operating Instructions and Parts Manual LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 12: Warranty Registration

    WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

This manual is also suitable for:

Ra250ngdgd

Table of Contents