Download  Print this page

KYMCO GRAND DINK 250 Manual: Right Crankcase Cover Removal; Stator Removal; Flywheel Removal

Hide thumbs

Advertisement

10
. A.C. GENERATOR/STARTER CLUTCH
RIGHT CRANKCASE COVER
REMOVAL
Disconnect the water hoses from the right
crankcase cover.
Remove the nine bolts attaching the right
crankcase cover and the cover.

STATOR REMOVAL

Remove the two pulser coil attaching screws
and the pulser coil.
Remove the three A.C. generator stator bolts
and the stator.
When removing the pulser coil and
stator, be careful not to damage them to
avoid shorted or broken wire.

FLYWHEEL REMOVAL

Hold the flywheel with a flywheel holder and
remove the flywheel nut.
Remove the flywheel with a flywheel puller.
10-3
GRAND DINK 250
Bolts
A.C. Generator Stator
Bolts
Flywheel Holder
Flywheel
Flywheel Puller
Water Inlet Hose
Water Outlet Hose
Screws
Pulser Coil
Nut