3.3 Adjustments Method

3.3.1 Factory Mode Access

(1) Enter a window pattern input of Input Signal 15 (VESA 1280 × 1024 (75Hz)).
(2) Pressing the [MENU] key and [ + (DVI/D-SUB)] key, press the power key from ON → OFF
simultaneously, then press [MENU] key in order to obtain a display of the [Factory Mode] screen.
NMV1700NX
1 2 3 4 5
AUTO BALANCE
OFFSET RED
OFFSET GREEN
OFFSET BLUE
GAIN RED
GAIN GREEN
GAIN BLUE
(3) Factory mode is closed by turning OFF → ON the POWER key.

3.3.2 Factory Preset

(1) Select page 4.
(2) Using the [6] key, select [FACTORY PRESET].
(3) When the [ − (AUTO)] key or [ + (DVI/D-SUB)] key is pressed, HOURS RUNNING, AUTO ADJUST
COUNT, AUTO INFORMATION, and user's setting values are cleared.
NMV1700NX
1 2 3 4 5
VERSION
F012
02/04/17
FACTORY PRESET
88
91
96
251
254
254
4-6