CHOOSING YOUR INSTALLATION

We recommend that you install this ap-
pliance in a work top which is a minimum
38mm deep.
The hob can be fitted into a work top
less than 38mm deep, but the 25mm gap
between hob base and appliance must be
maintained.
Installation above an oven
Refer to the manufacturer's instructions
for clearances above the oven.
INSTALLATION ABOVE AN OVEN
We recommend a 25mm gap between the
bottom of the hob and appliance.
Installation above a unit with a
Worktop
drawer or door
The base of the appliance must be pro-
tected from damage e.g. drawers may
only be installed providing a partition
Oven
panel is fitted to the required dimensions
underneath the appliance.
INSTALLATION ABOVE A UNIT WITH
A DRAWER OR DOOR
Worktop
Partician
Partition
INSTALLATION
Hob
25mm
Hob
25mm

Ventilation Requirements

The room containing the appliance
should have an air supply in accordance
with BS5440: Part 2
• All rooms require an openable
window, or equivalent, and some
rooms will require a permanent
vent as well.
• For room volumes up to 5m3 an air
vent of 100cm2 is required.
• If the room has a door that opens
directly to the outside, or the room
exceeds 10m3 NO AIR VENT is
required.
• For room volumes between 5m3
and 10m3 an air vent of 50cm2 is
required.
• If there are other fuel burning
appliances in the same room, BS
5440: Part 2: (or equivalent) should be
consulted to determine the air vent re-
quirements.
• This appliance must not be
installed in a bed sitting room of
less than 20m3 or in a bathroom or
shower room.
• Windows and permanent vents
should therefore not be blocked or
removed without first consulting a
compenent engineer.
LP Gas only - Do not install this
appliance in a room below ground
level. This does not preclude installation
into rooms which are basements
with respect to one side of the building
but open to ground level on the opposite
side.
For installation into environments other
than domestic dwellings, e.g. caravans,
boats and similar - refer to the
relevant standards on ventilation and
gas supply.
Failure to install appliances correctly
is dangerous & could
lead to prosecution.
13.300