• The maximum wire run distance between the first and last unit in an intercon-
nected system is 1000 feet.
• Figure 4 illustrates interconnection wiring. Improper connection will result in
damage to the alarm, failure to operate, or a shock hazard.
• Make certain alarms are wired to a continuous (non-switched) power line.
NOTE: Use standard UL listed household wire (as required by local codes) avail-
able at all electrical supply stores and most hardware stores.
FUSE OR CIRCUIT BREAKER
WHITE
RED
BLACK
CONNECTOR
First
Alarm
FIGURE 4 INTERCONNECT WIRING DIAGRAM
WIRES ON ALARM HARNESS
Black
White
Red

BATTERY INSTALLATION

See MAINTENANCE (Section 6) for battery installation.
CAUTION! THIS UNIT WILL NOT FUNCTION WITHOUT A PROPERLY
INSTALLED BATTERY, AND IS EQUIPPED WITH A BATTERY LOCKOUT FEA-
TURE WHICH PREVENTS THE BATTERY CARRIER FROM CLOSING IF A BAT-
TERY IS NOT INSTALLED CORRECTLY.

MOUNTING INSTRUCTIONS

CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT
REMOVABLE!
CAUTION: WHEN WALL MOUNTING: UNIT MUST BE
MOUNTED SO THAT THE BATTERY BOX FACES
DOWN! (SEE FIGURE 5). INCORRECT ORIENTATION
OF WALL MOUNTED SMOKE ALARMS WILL
DECREASE OPERATIONAL EFFECTIVENESS.
Additional
Alarm
CONNECTED TO
Hot Side of A.C. Line
Neutral Side of A.C. Line
Interconnect Lines (Red Wires) of Other
Units in the Multiple Station Set up
Kidde
Relay Module
SM120X
Optional
Accessory
WHITE
BLACK
Additional
Alarm
FIGURE 5
RED
CONNECTOR