Emerson 1F94-80 Operation Manual page 14

7 day multi-stage/heat pump electronic digital thermostat
Table of Contents

Advertisement

the highest heat setting and the lowest cool
setting to be less than 1°F. For example, if
the highest heat setting is 76°F, the lowest
cool setting cannot be below 77°F (see
diagram below).
79
COOLING TEMPERATURES
78
77
76
75
HEATING TEMPERATURES
74
• TWO HOUR TEMPERATURE OVER-
RIDE — Press
display shows the temperature you want.
The thermostat will override current pro-
gramming and keep the room temperature
at the selected temperature for two hours.
After two hours, the thermostat will auto-
matically revert to the program.
14
DEAD BAND
or
until the
We do not recommend using the temperature
override feature when the thermostat is in the
AUTO mode. If you press
AUTO mode, the thermostat will revert to the
mode (heat or cool) in which it last cycled and will
prevent automatic switching for two hours. If you
do press
or
may press
RUN
to return to programmed opera-
PRGM
tion in the AUTO mode.
• HOLD TEMPERATURE — The thermostat
can hold any temperature within its range
for an indefinite period, without reverting to
the program. Press
played. Then choose the desired hold tem-
perature by pressing
NOTE
or
in the AUTO mode, you
HOLD
. HLD will be dis-
COPY
or
in the
. The