Mitsubishi Electric Mr.Slim PUHZ-ZRP35VKA Service Manual page 109

Split-type, heat pump air conditioners r410a
Hide thumbs Also See for Mr.Slim PUHZ-ZRP35VKA:
Table of Contents

Advertisement

Request content
50
Indoor unit-Control state
Outdoor unit-Control state
51
52
Compressor-Frequency control state
53
Outdoor unit-Fan control state
Actuator output state
54
Error content (U9)
55
56
57
58
59
Signal transmission demand capacity
60
Contact demand capacity
61
62
External input state (silent mode, etc.)
63
64
65
66
67
68
69
Outdoor unit-Capacity setting display
70
Outdoor unit-Setting information
71
72
Outdoor unit-SW1 setting information
73
Outdoor unit-SW2 setting information
74
75
Outdoor unit-SW4 setting information
76
Outdoor unit-SW5 setting information
77
78
Outdoor unit-SW6 setting information
Outdoor unit-SW7 setting information
79
Outdoor unit-SW8 setting information
80
81
Outdoor unit-SW9 setting information
82
Outdoor unit-SW10 setting information
83
84
M-NET adapter connection (presence/absence)
85
86
87
88
89
Display of execution of replace/wash operation
Outdoor unit-Microprocessor version information
90
91
Outdoor unit-Microprocessor version information (sub No.)
92
93
94
95
96
97
98
99
100
Outdoor unit - Error postponement history 1 (latest)
Outdoor unit - Error postponement history 2 (previous)
101
102
Outdoor unit - Error postponement history 3 (last but one)
OCH527
Description
(Display range)
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
0 – 255
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
Refer to 12-1-2.Detail Contents in Request Code.
"0000": Not connected
"0001": Connected
"0000": Not washed
"0001": Washed
Examples) Ver 5.01
"0501"
Auxiliary information (displayed after
version information)
Examples) Ver 5.01 A000
"A000"
Displays postponement code. (" - - " is
displayed if no postponement code is present)
Displays postponement code. (" - - " is
displayed if no postponement code is present)
Displays postponement code. (" - - " is
displayed if no postponement code is present)
109
Unit
Remarks
%
Ver
Code
Code
Code

Hide quick links: