Alarm Log (Receiver); Remote Site Clock Setup [620]; Communication Rate /Information Verification [630] - Panasonic WJ-AV20 Operating Instructions Manual

Av codec
Table of Contents

Advertisement

Alarm Log (Receiver)

6 1 2
A L A R M
L O G ( R E C E I V E R )
N O .
D A T E
1 0 0
1 5 / 0 7 / 9 9
9 9
. . / . . / . .
9 8
. . / . . / . .
9 7
. . / . . / . .
9 6
. . / . . / . .
9 5
. . / . . / . .
9 4
. . / . . / . .
9 3
. . / . . / . .
9 2
. . / . . / . .
9 1
. . / . . / . .
: N E X T
A L M
Date when alarm occurred

Remote Site Clock Setup [620]

6 2 0
R E M O T E
C L O C K
R E M O T E
C L O C K
P R E S S
E N T
T O
L O C A L
C L O C K .
E N T : E X E C
E S C : P R V
Communication Rate/Information Verification [630]
Communication information is shown if trouble occurs that disconnects the communication or causes connection failure.
If the line is frequently disconnected during communication, call this menu to the screen and verify the cause. After verifying
the cause, review the system settings and modify them if necessary.
6 3 0
C O M
R A T E / I N F O
C O M
S T A T E / D I S C
1 B : #
2 B : #
C O M
I N F O . :
E S C : P R V
59
T I M E
T I T L E / N O .
1 4 : 3 4 : 0 1
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
. . : . . : . .
. . . . . . . . . .
: P R V
A L M
D E L : C L R
E S C : P R V
Dialing site names (Calling numbers are shown if calls are received
from sites not registered in the directory.)
Time when alarm occurred (Time
of alarm input to remote site)
S E T
S E T :
E X E C
K E Y
T O
S E T
R E M O T E
C L O C K
V A L E :
A L M #
3
SENSOR IN connector No. where alarm is input
.
.
.
.
.
.
Log received during communication
(Dates and hours of receiving the log as indicated by the control site
.
.
clock are shown.)
Notes
• The time data recorded in the alarm log is based on
the time at the remote site.
The log of alarms received during communication is
based on the time at the control site.
• If a call is received during communication when a
PBX or other exchange is used, the same settings
may be recorded twice.
Move the cursor to [EXEC] and press the ENTER button.
Adjust the remote site clock to the time of the control site.
Notes
The time of the control site is reported via the network
so the time set at the remote site has an error of about
±2 seconds. (The error varies depending on the com-
munication route.)
Cause display
Communication information display