Override Locked Scanner

If you need to replace a broken or lost scanner that is linked to a base or an
Access Point, scan the Override Locked Scanner bar code below with a
new scanner and place that scanner in the base, or scan the Access Point
linking bar code. The locked link will be overridden; the broken or lost
scanner's link with the base or Access Point will be removed, and the new
scanner will be linked.

Out-of-Range Alarm

If your scanner is out range of the base, an alarm sounds from both your base
and scanner. If your scanner is out range of an Access Point, an alarm sounds
from just the scanner. The alarm stops when the scanner is moved closer to the
base or Access Point, when the base or Access Point connects to another scan-
ner, or when the alarm duration expires. To activate the alarm options for the
scanner or the base and to set the alarm duration, scan the appropriate bar
code below and then set the time-out duration (from 0-3000 seconds) by scan-
ning digits on the
Save. Default = 0 sec (no alarm).
Base Alarm Duration
Note:
The Access Point does not
have a base alarm.
Note: If you are out of range when you scan a bar code, you will receive an error
tone even if you do not have the alarm set. You receive the error tone
since the data could not be communicated to the base or Access Point or
the host.

Alarm Sound Type

You may change the alarm type for the scanner or a CCB01-010BT base
by scanning the appropriate bar code below and then scanning a digit (0-7)
bar code and the Save bar code on the
cover of this manual. Default = 0.
Override Locked Scanner
(Single Scanner)
Programming Chart
inside the back cover, then scanning
Scanner Alarm Duration
Programming Chart
inside the back
3 - 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Granit 1911iXenon 1910Granit 1910iXenon 1902Xenon 1912

Table of Contents