Honeywell Xenon 1900 User Manual page 252

Area-imaging scanner
Hide thumbs Also See for Xenon 1900:
Table of Contents

Advertisement

J - JPEG Image Quality
Sets the desired quality when the JPEG image format is selected. Higher
numbers result in higher quality, but larger files. Smaller numbers result in
greater amounts of lossy compression, faster transmission times, lower
quality, but smaller files. (Default = 50)
n J Image is compressed as much as possible while preserving quality
factor of n ( n = 0 - 100)
0J worst quality (smallest file)
100Jbest quality (largest file)
K - Gamma Correction
Gamma measures the brightness of midtone values produced by the
image. You can brighten or darken an image using gamma correction. A
higher gamma correction yields an overall brighter image. The lower the
setting, the darker the image. The optimal setting for text images is 50K.
0K Gamma correction off (default)
50K Apply gamma correction for brightening typical document image
n K Apply gamma correction factor n ( n = 0-1,000)
Example of Gamma
Correction set to 0K:
L, R, T, B, M - Image Cropping
Ships a window of the image by specifying the left, right, top, and bottom
pixel coordinates. Device columns are numbered 0 through 1279, and
device rows are numbered 0 through 959.
n L The left edge of the shipped image corresponds to column n of the
image in memory. Range: 000 - 843. (Default = 0)
n R The right edge of the shipped image corresponds to column n - 1
of the image in memory. Range: 000 - 843. (Default = all
columns)
n T The top edge of the shipped image corresponds to row n of the
image in memory. Range: 000 - 639. (Default = 0)
8 - 10
Example of Gamma
Correction set to 50K:
Example of Gamma
Correction set to 255K: