Flasher relay input voltage
DC 12V
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
a. Connect the pocket tester (DC 20 V) to the
flasher relay terminal.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe →
Blue/Red "1"
Negative tester probe →
Ground
b. Set the main switch to "ON".
c. Measure flasher relay applied voltage.
LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL
2. Check:
Flasher relay output voltage
G
Out of specification → Replace.
Flasher relay output voltage
DC 12V
MMMMMMMMMMMMMMMMMMMMMMMMMMMMMMMM
a. Connect the pocket tester (DC 20 V) to the
flasher relay terminal.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe →
Brown/White termnals "1"
Negative tester probe →
Ground
Br/W
L/R
1
ELECTRICAL COMPONENTS
b. Set the main switch to "ON".
c. Measure flasher relay applied voltage.
LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL
EAS28050
CHECKING THE DIODE
1. Check:
Diode
G
Out of specification→Replace the relay unit.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
NOTE:
Checking method using pocket tester (analog
tester).
7-91
Br/W
L/R
1