Honeywell evohome Installation Manual page 8

Sundial pack thermostat
Hide thumbs Also See for evohome:
Table of Contents

Advertisement

Mounting CS92A transceiver
The CS92A transceiver is supplied in
the package with the mounting plate
separated from the rest of the unit for ease
of installation.
The sensor wiring can be fed in from the top
of the mounting plate or from the left hand
side.
• Cut a suitable hole in the appropriate
plastic breakout.
• Install the CS92A transceiver mounting
plate in the chosen location next to the
hot water cylinder.
Wiring the CS92A transceiver
• Lead the 2 sensor wires through the
mounting plate and connect them
to terminals A and B on the CS92A
mounting plate as shown. The wires are
polarity free, so they can be connected in
any order.
8
• Provide appropriate strain relief by
attaching the sensor cable to the wall
using cable clips, or alternatively run the
cable in mini trunking.
Powering up CS92A / Battery
replacement
• First hold the transceiver approximately
1 metre from evotouch.
• To power it up, unclip the battery cover,
remove the paper tab that isolates the
batteries from their contacts, and replace
the battery cover.
• When replacing batteries note the battery
polarity.
Closing CS92A transceiver
• Hinge the front piece of the CS92A
transceiver onto the mounting plate and
press until it clicks securely into place.

Hide quick links:

Advertisement

Table of Contents
loading