Securing The Wall Plate To The Wall (Or Corner Plate To A Corner, Or Mast Plate To A Mast) - Bosch AutoDome Mounting Manual

Wall, corner, mast (pole), roof (parapet), pipe
Hide thumbs Also See for AutoDome:
Table of Contents

Advertisement

EN
O-Ring Gasket
Photo 4B
4.1.3. The fittings shown in the photo are
tight conduit fittings with a gasket and a nut to secure
it in place.
NOTE: AC Power wiring and Control/Video wiring must be
kept separate, entering the pendant arm box through separate
entry holes.
4.1.4. Cut and trim the cables as follows:
If the unit has a transformer (PA1 & PA2 models), trim
ν
ALL extending cables to 15 cm (6-inches) beyond the
plate.
If the unit has no transformer (PA0 models), trim the
ν
VIDEO CABLE extending through the plate to 15 cm
(6-inches), and trim the 24 VAC and data cables to
75 cm (30-inches) beyond the plate to allow slack
when feeding the cable through the arm.
NOTES:
If using the Alarms on the AutoDome, trim the wires
ν
for the Alarm connections in the same manner as
above.
Inspect the enclosure fittings after installation to ensure
ν
that the gaskets have not been damaged, replacing as
necessary.
4.2
Securing the Wall Plate to the Wall (or
Corner Plate to a Corner, or Mast Plate to a
Mast)
4.2.1. Remove the pendant arm box from the wall mounting
plate so that the plate with the four (4) carriage bolts
(supplied) may be mounted by itself (as shown in
PHOTO 4C).
© 2003 Bosch Security Systems
Locking Ring
-inch PVC water-
3
4
Photo 4C
4.2.2. If the wires are to run through the back of the plate,
feed them from the wall through the two (2) liquid-
tight (or other) fittings in the wall plate. Observe the
labels on the plate indicating that the left-hand side is
for POWER and the right-hand side is for
SIGNAL and VIDEO.
4.2.3. Secure the wall (or corner) plate to the wall using four (4)
fasteners (not included) that can each withstand
120 kg (265 lb) pull-out force. A minimum 0.64 cm
-inch) stud (maximum of 10 mm [
(
1
4
equivalent is recommended.
4.2.4. If using the Corner or Mast plate, secure the wall plate
to this plate using the four (4) 3/8" x 1" bolts supplied
(as shown in PHOTO 4D).
Photo 4D
NOTES:
For mast mounting, the Banding Tool (TC9311PM3T,
ν
sold separately) is required to mount the mast plate (see
PHOTO 4E). Follow the mounting instructions provided
with the tool to mount the mast plate securely to a pole.
Two (2) straps and two (2) band clips are included with
the Mast Mount Kit.
To prevent possible condensation buildup when connect-
ν
ed to conduit, use some of the foam packing material to
block the air from the conduit once the wires have been
pulled through.
Installation
-inch] stud) or
3
8
Wall Plate
Mast Plate
Page 9 of 24

Advertisement

Table of Contents
loading

Table of Contents