EN
NOTE: The shipping carton and all packing materials should
be retained, in case transporting the unit is necessary. This will
ensure safe transport of all components.
3

TOOLS REQUIRED

3
-inch wrench or socket
ν
8
-inch wrench or socket
5
ν
1 6
16 mm wrench or socket (if using metric fasteners)
ν
Standard screwdriver
ν
Thread sealant or pipe tape
ν
Other tools as needed for preparing the mounting surface
ν
4

ACCESSORIES (Not Included)

LTC 9230/01 Flat Roof Adapter for Parapet Mount
5

INSTALLATION

5.1

Rough Wiring

Whether using the supplied transformer (ENV-PSU) or anoth-
er approved 24 VAC power supply, refer to APPENDIX A for
distance limitations from dome.
Photo 5A Power Supply Enclosure
5.2

Mounting the Transformer Box ENV-PSU

ATTENTION: POWER and CONTROL wiring MUST enter
the box through separate holes.
5.2.1. If wiring the Power Supply box through the bottom of
the enclosure instead of the back, remove the plugs
from the bottom of the box (as shown in PHOTO 5A),
and use them to close the holes in the back of the
mounting plate.
5.2.2. Remove the box from the mounting plate so that the plate
with the four (4) carriage bolts (supplied) may be mount-
ed separately.
5.2.3. Use only liquid-tight fittings or liquid-tight conduit fit-
tings in the two (2) holes in the back of the mounting
plate, or the bottom of the power supply unit. When
using liquid-tight fittings, it is important to use the
appropriate cable width for a snug fit. If a snug fit is
not possible, any liquid-tight
may be used instead.
© 2003 Bosch Security Systems
3
-inch conduit fitting
4
O-Ring Gasket
Photo 5B
NOTE: The fittings shown in the photos are some examples
of
3
-inch PVC watertight conduit fittings with an O-Ring
4
gasket and locking nut.
5.2.4. If the wires are to connect through the back of the
mounting plate, feed them through the liquid-tight or
conduit fittings in the mounting plate.
5.2.5. Secure the mounting plate to a stable surface; using
four (4) fasteners (not included) that can each with-
stand 120 kg (265 lb). A minimum 0.64 cm (
stud (maximum of 10 mm [
is recommended.
5.2.6. Remove the input POWER and SIGNAL connectors
from the board.
5.2.7. Strip the wires and connect the appropriate connectors
to the stripped wires, then tighten the screws
securely(see FIGURE 1).
CONTROL CONNECTOR
9
8
7
6
5
C–
C+ GND RXD TXD GND H
Biphase
RS-232
Ground
Ground
Biphase +
RS-232/*
Biphase –
RS-232/*
Figure 1
5.2.8. If the AutoTracker option is being used, the RS-232
connections (RXD,TXD and GND) must be wired. The
data cable used should be twisted and shielded, with a
maximum distance of 50 feet.
* If the internal slide switch is set for RS-485
operation, then RXD functions as DATA (+),
and TXD functions as DATA (–).
5.2.9. Per PHOTO 5C, connect the EARTH GROUND to the
green screw.
5.2.10.Connect the CONTROL and POWER connectors to
the board.
Installation
Locking Ring
1
-inch)
4
3
-inch] stud) or equivalent
8
4
3
2
1
24 VAC
Retaining
Screw
24 VAC Hot
24 VAC Neutral
Indoor Pendant - Not Connected
EnviroDome
®
- 24 VAC Heater
Page 14 of 24