Black Box 16-Port Rackmount 10/100 Installation Manual page 52

Serial terminal servers
Hide thumbs Also See for 16-Port Rackmount 10/100:
Table of Contents

Advertisement

Table 11-1: Power-up Problems and Error Messages, cont.
Problem/Message Error
The terminal shows a
Boot> prompt rather
than a Local>
prompt.
The Terminal Server
passes power-up
diagnostics, but
attempts to download
new Flash ROM
code from a network
host.
46
The Terminal Server is not con-
nected properly to the Ethernet.
The Terminal Server Ethernet
address is invalid.
Init Noboot command was
entered.
If the OK LED blinks rapidly,
the Flash ROM code may be
corrupt.
If you did not request a TFTP
boot, the flash ROM code is
corrupt. The unit will remain in
boot mode.
Remedy
Ensure that the Terminal Server is firmly
connected to a functional and properly-
terminated network node.
The Terminal Server Ethernet address is
located on the bottom of the unit. Use the
Change Hardware command to set the
correct address, then reboot.
See Modem Configuration Checklist on
page 48.
Reboot the unit. If you get the same mes-
sage, you will need to reload Flash ROM.
See Reloading Software on page 56.

Advertisement

Table of Contents
loading

This manual is also suitable for:

32-port rackmount 10/100

Table of Contents