Installation And Connection - Miele PT 8251 + COP Operating Instructions Manual

Hide thumbs Also See for PT 8251 + COP:
Table of Contents

Advertisement

Installation and connection

This machine must only be installed and commis-
sioned by a Miele authorised technician.
This appliance must be installed in
accordance with local and national safety
and building regulations by a suitably
qualified engineer (Gas Safe registered in
the UK). It must only be operated in a room
with sufficient ventilation.
Read the instructions supplied with the appliance
before installing and using it for the first time.
Do not install the tumble dryer in a room where there
is a risk of frost occurring.
,
The machine must not be transported without
its transport pallet in position.
Once the dryer reaches its final location, use a
suitable lifting mechanism to lift the dryer off its
transport pallet.
20
To ensure suitable access is maintained for future
maintenance and service work, please ensure that
the minimum distances between the machine and the
wall as specified on the installation diagram are
strictly observed.
PT 825X / 833X / 840X
x
1400 mm
y
906 mm
z
836 / 1019 / 1148 mm
PT 850X / 880X
1640 mm
1206 mm
1002 / 1368 mm