Kenwood TK-860G Service Manual Supplement page 25

Uhf fm transceiver
Hide thumbs Also See for TK-860G:
Table of Contents

Advertisement

Item
Condition
9. QT deviation 1) Set test mode
• Wide
Select "FQT" in tuning mode. Deviation
"_.FQT"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
2) "_.F.Q.T"
PTT : ON
Adjust [ *** ]
3) "_.F.Q.T._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "_FQT *** ."
PTT : ON
Adjust [ *** ]
10. DQT
1) Set test mode
deviation
Select "FDQT" in tuning mode.
• Wide
"F.DQT"
Deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
2) "F.D.Q.T"
PTT : ON
Adjust [ *** ]
3) "F.D.Q.T._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "FDQT *** ."
PTT : ON
Adjust [ *** ]
11. DTMF
1) Set test mode
deviation
Select "DTMF" in tuning mode.
• Wide
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
• Narrow
2) "DTMF *** ."
PTT : ON
Adjust [ *** ]
12. TONE
1) Set test mode
deviation
Select "TONE" in tuning mode.
• Wide
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
Adjust [ *** ]
• Narrow
2) "TONE *** ."
PTT : ON
Adjust [ *** ]
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Front
panel
panel
meter
Oscilloscope
AF VTVM Front
MIC
AG
panel
Front
panel
Front
panel
Front
panel
TK-860G/862G
Adjustment
Parts
Method
CH /
0.75kHz
0.35kHz
CH /
0.75kHz
0.35kHz
CH /
3.0kHz
1.5kHz
CH /
3.0kHz
1.5kHz
Specifications/Remarks
50Hz (Wide/Narrow)
50Hz (Wide/Narrow)
0.2kHz
0.1kHz
0.1kHz (Wide/Narrow)
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-862g

Table of Contents