Sharp MX-M350 Service Manual page 187

Hide thumbs Also See for MX-M350:
Table of Contents

Advertisement

46-24
Purpose
Adjustment
Function
Used to adjust the scanner exposure level in the
(Purpose)
super fine text mode.
Item
Picture quality
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
∗ Normal mode (Image density adjustment level)
∗ Normal mode (Image density adjustment level) (Half-tone
mode)
∗ Auto mode
∗ Auto mode (Half-tone mode)
2) Press [START] key.
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
Item
0
AUTO
Auto
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
6
AUTO (H)
Auto (Half-tone)
7
1.0 (H)
Exposure level 1 (Half-tone)
8
2.0 (H)
Exposure level 2 (Half-tone)
9
3.0 (H)
Exposure level 3 (Half-tone)
10 4.0 (H)
Exposure level 4 (Half-tone)
11 5.0 (H)
Exposure level 5 (Half-tone)
NOTE: Only the set value is changed and no printing is performed.
SIMULATION 46-24
EXP.LEVEL SETUP SCANNER(SUPER FINE). SELECT 0-11,AND
PRESS START.
0.AUTO
50
1.1.0
50
3.3.0
50
4.4.0
50
6.AUTO(H)
50
7.1.0(H)
50
9.3.0(H)
50
10.4.0(H)
50
Select other than 0 - 11, and
press [START] key.
SIMULATION 46-24
EXP.LEVEL SETUP SCANNER(SUPER FINE). INPUT VALUE 0-99,
AND PRESS START.
0.AUTO
Density
Set
Default
range
0 - 99
2.2.0
50
1
5.5.0
50
8.2.0(H)
50
11.5.0(H)
50
Press [START] key, or
press [SYSTEM SETTINGS] key.
50
MX-M350/M450 N/U SIMULATION 9 - 48
46-25
Purpose
Adjustment
Function
Used to adjust the scanner exposure level in the
(Purpose)
ultra fine text mode.
Item
Picture quality
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
∗ Normal mode (Image density adjustment level)
∗ Normal mode (Image density adjustment level) (Half-tone
mode)
∗ Auto mode
∗ Auto mode (Half-tone mode)
2) Press [START] key.
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
50
0 AUTO
Auto
1 1.0
Exposure level 1
2 2.0
Exposure level 2
3 3.0
Exposure level 3
4 4.0
Exposure level 4
5 5.0
Exposure level 5
6 AUTO (H)
Auto (Half-tone)
7 1.0 (H)
Exposure level 1 (Half-tone)
8 2.0 (H)
Exposure level 2 (Half-tone)
9 3.0 (H)
Exposure level 3 (Half-tone)
10 4.0 (H)
Exposure level 4 (Half-tone)
11 5.0 (H)
Exposure level 5 (Half-tone)
NOTE: Only the set value is changed and no printing is performed.
SIMULATION 46-25
EXP.LEVEL SETUP SCANNER(ULTRA FINE). SELECT 0-11,AND
PRESS START.
0.AUTO
50
1.1.0
3.3.0
50
4.4.0
6.AUTO(H)
50
9.3.0(H)
50
Select other than 0 - 11, and
press [START] key.
SIMULATION 46-25
EXP.LEVEL SETUP SCANNER(ULTRA FINE). INPUT VALUE 0-99,
AND PRESS START.
0.AUTO
Item
range
0 - 99
50
2.2.0
50
50
5.5.0
50
7.1.0(H)
50
8.2.0(H)
50
10.4.0(H)
50
11.5.0(H)
50
Press [START] key, or
press [SYSTEM SETTINGS] key.
Density
Set
Default
50
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M450 uM450 n

Table of Contents