Code
Function (Purpose)
Main
Sub
24
3
Used to clear the number of use of the finisher,
SPF, and the scan (reading) unit.
4
Used to reset the maintenance counter.
5
Used to reset the developer counter. (The
developer counter of the DV unit which is installed
is reset.)
6
Used to reset the copy counter.
7
Used to clear the OPC drum counter. (Perform this
simulation when the OPC drum is replaced.)
9
Used clear the printer mode print counter and the
self print mode print counter.
10
Used to clear the FAX counter. (Only when FAX is
installed)
11
Used to reset the OPC drum rotation time, and the
DV unit rotation time counter. The developer
counter in the DV unit installed is reset.
15
Used to clear the counters related to the scan
mode and the Internet FAX mode.
25
1
Used to check the operations of the developing
section (toner concentration, humidity and toner
concentration sensor, humidity sensor,
temperature sensor output can be monitored.)
2
Used to make the initial setting of toner
concentration when replacing developer.
26
3
Used to set the specifications of the auditor.
Setting must be made according to the auditor use
conditions.
5
Used to set the count mode of the total counter
and the maintenance counter.
6
Used to set the specifications (paper, document
detection, etc.) of the destination.
10
Used to set the network scanner trial mode.
18
Used to set YES/NO of toner save operation. (This
function is valid only in Japan and UK versions.
(Depends on the destination setting of SIM26-6.)
For the other destinations, the same setting can be
made by the user program P22.)
30
Used to set the operation mode conforming to the
CE mark (Europe safety standards). (Conforming
to soft start when driving the fusing heater lamp.)
35
Used to set whether the same continuous troubles
are displayed as one trouble or the series of
troubles with SIM 22-4 when the same troubles
occur continuously.
38
Used to set CONTINUE/STOP of printing when
maintenance timing is over and the count value
reaches 110% of replacement timing (life).
41
Used to set the automatic magnification ratio
selection (AMS) in the pamphlet mode.
50
Black-White reverse YES/NO setting (Except for
UK)
52
Used to set whether non-print paper (insertion
paper, cover paper) (blank image print paper) is
counted up or not.
68
Used to set ENABLE/DISABLE of the CA key
cancel function of print stop.
27
1
Used to set the specifications for operations in
case of communication trouble between the host
computer and MODEM (machine side). (When
communication trouble occurs between the host
computer MODEM and the machine, the self diag
display (U7-00) is printed and setting for inhibition
of print or not is made.)
5
Used to enter the machine tag No. (This function
allows to check the tag No. of the machine with the
host computer.)
Code
Main
30
40
41
43
44
46
MX-M350/M450 N/U SIMULATION 9 - 4
Function (Purpose)
Sub
1
Used to check the operation of sensors and
detectors in other than the paper feed section and
the operations of the related circuits.
2
Used to check the operation of sensors and
detectors in the paper feed section and the related
circuits.
1
Used to check the operation of the manual feed
tray paper size detector and the related circuit.
(The operation of the manual feed tray paper size
detector can be monitored with the LCD display.)
2
Used to adjust the manual paper feed tray paper
width detector detection level.
7
Used to enter the manual paper feed tray paper
width adjustment value.
11
Used to check the multi-purpose tray width
detection level.
12
Used to adjust the multi-purpose tray width
detection level.
1
Used to check the operation of the document size
sensor and the related circuit. (The operation of
the document size sensor can be monitored with
the LCD display.)
2
Used to adjust the document size sensor sensing
level.
3
Used to check the operation of the document size
sensor and the related circuit. (The document size
sensor output level can be monitored with the LCD
display.)
1
Used to set the fusing temperature in each
operation mode.
1
Used to set enable/disable of correction operations
in the image forming (process) section.
4
Used to set the target image (reference) density
level in the developing bias voltage correction.
9
Used to check the data related to the image
forming section correction (process correction)
result (corrected main charger grid voltage, the
developing bias voltage, and the laser power
voltage in each print mode). (This simulation
allows to check that correction is performed
normally or not.)
14
Used to check the output level of the temperature
sensor and the humidity sensor.
16
Used to check the toner concentration control
data.
2
Used to adjust the copy density in all the copy
modes (Auto, Text, Text/Photo, and Photo mode).
9
Used to adjust the print density for each density
level (display value) in the copy mode (binary - Text
mode). An optional print density can be set for
each density level (display value).
10
Used to adjust the print density for each density
level (display value) in the copy mode (binary -
Text/Photo mode). An optional print density can be
set for each density level (display value).
11
Used to adjust the print density for each density
level (display value) in the copy mode (binary -
Photo mode). An optional print density can be set
for each density level (display value).
12
Used to adjust the print density in the FAX mode
(all modes).
13
Used to adjust the print density in the FAX mode
(each normal mode). (Only when FAX is installed.)
14
Used to adjust the print density in the FAX mode
(each fine mode). (Only when FAX is installed.)