Replacing Shut-Off Valve (Cwg3100Aa*); Replacing Burner Fitting (Cwg3600Aa*); Replacing Rocker (Oven Light) Switch; Replacing Control Panel Assembly - Maytag CWG3100AA Series Service Manual

24” gas wall ovens
Hide thumbs Also See for CWG3100AA Series:
Table of Contents

Advertisement

Disassembly Procedures

Replacing Shut-off Valve (CWG3100AA*)

1. Remove oven bottom, see "Removing Oven Bottom"
procedure.
2. Remove screws securing oven valve cover.
3. Disconnect gas supply lines from valve.
4. Disconnect screws securing valve to support
brackets.
5. Slide valve out to remove.
6. Reverse procedures to reassemble.

Replacing Burner Fitting (CWG3600AA*)

1. Remove oven burner, see "Replacing Oven Burner"
procedure (do not perform step 2).
2. Disconnect gas lines from burner fitting.
3. Remove screws securing burner fitting to support
bracket.
4. Slide burner fitting out to remove
5. Reverse procedures to reassemble.
Oven Valve
Cover
Gas Tubing
Pressure Regulator
and Support Bracket
Model CWG3100AA* Gas Controls

Replacing Rocker (Oven Light) Switch

1. Remove control panel assembly, see "Replacing
Control Panel Assembly" procedure.
2. Label and disconnect wire terminals from rocker
switch.
3. Squeeze tabs on rocker switch and push outward to
remove.
4. Reverse procedures to reassemble.

Replacing Control Panel Assembly

1. Remove power from unit (at the circuit breaker).
2. Remove screws securing rear cover and remove.
3. Remove screws securing wire cover and remove.
4. Remove screws securing control panel assembly.
©2005 Maytag Services
To avoid risk of electrical shock, personal injury or
death; disconnect power and gas before servicing,
unless testing requires power and/or gas.
5. Lower and remove control panel assembly and
6. Remove screws securing clock (and overlay) to
7. Reverse procedures to reassemble.
Oven Burner
Oven Light Assembly
Oven Light Bulb/Oven Light Socket
1. Remove power from unit (at the circuit breaker).
Ignitor
2. Open oven door and remove oven racks.
3. Hold lamp cover in place, and slide retaining wire off
Shut-off Valve
and Support Bracket
NOTE: Cover will fall if not held in place when removing
4. Unscrew lamp and remove.
5. Gently pry retaining clips inward towards center of
6. Once retaining clips are released, gently pull socket
7. Label and disconnect wire terminal connections and
8. Reverse procedure to reassemble.
NOTE: Reposition fiberglass insulation around oven
16026549
backing plate.
control panel and backing plate.
Wire Cover
Top, Front Extrusion
Clock w/Overlay
Backing Plate
Oven Light
Switch
Control Panel
Vent Extrusion
Control Panel Assembly
cover.
Lamp
(40 watts)
Lamp
Cover
Lamp and Socket
retaining wire.
socket.
into oven cavity.
remove socket.
light socket to eliminate possibility of heat
related problems.
Rear Cover
Retaining Clip
Lamp
Socket
Retaining Clip