Temperature Sensors; Door Switch; Compressor Compartment - Electrolux ERF2000 Service Manual

Hide thumbs Also See for ERF2000:
Table of Contents

Advertisement

4.3.1 Temperature sensors

3 NTC sensors are used to detect the temperatures of the two compartments:
freezer air temperature sensor A (located on the freezer cell);
cooler air temperature sensor B (located on the cooler cell);
cooler evaporator temperature sensor C (located on the cooler cell).
The sensors A, B and C feature the foamed cable inside the cabinet, therefore they are not replaceable (for
further information, please see Service Bulletin 599374122).

4.3.2 Door switch

The control of the cooler door opening is carried out by using the magnetic switch located on the display board.
The magnetic switch is activated by a magnet located inside the cooler door.
The control does not imply the activation of the open door alarm, but it is used to light up the lamp of the cooler
compartment.

4.4 Compressor compartment

Key:
A. compressor
B. electric valve
- ITZAA
14/26
599 38 43-56