3-58
ENGINE
CRANKSHAFT AND CONROD
CRANKSHAFT RUNOUT
• Support the crankshaft with "V" blocks as shown, with the two
end journals resting on the blocks.
• Set up the dial gauge, as shown.
• Rotate the crankshaft slowly to read the runout.
• Replace the crankshaft if the runout is greater than the limit.
Crankshaft runout:
Service Limit: 0.05 mm
09900-20607: Dial gauge (1/100 mm, 10 mm)
09900-20701: Magnetic stand
09900-21304: V-block set (100 mm)
CONROD SMALL END I.D.
• Using a small bore gauge, measure the inside diameter of the
conrod small end.
Conrod small end I.D.:
Service Limit: 14.040 mm
09900-20602: Dial gauge (1/1 000 mm, 1 mm)
09900-22401: Small bore gauge (10 – 18 mm)
• If the inside diameter of the conrod small end exceeds the
limit, replace the conrod.