Kenwood TK-760G Service Manual page 47

Vhf fm transceiver
Hide thumbs Also See for TK-760G:
Table of Contents

Advertisement

Test Equipment Required for Alignment
Test Equipment
1. Standard Signal Generator
(SSG)
2. Power Meter
3. Deviation Meter
4. Digital Volt Meter
(DVM)
5. Oscilloscope
6. High Sensitivity
Frequency Counter
7. Ammeter
8. AF Volt Meter
(AF VTVM)
9. Audio Generator (AG)
10. Distortion Meter
11. 4Ω Dummy Load
12. Regulated Power Supply
Tuning cable (E30-3383-05)
Adapter cable (E30-3383-05) is required for
injecting an audio if PC tuning is used.
See "PC Mode" section for the connection.
Lead wire +
Shield wire –
MIC
ADJUSTMENT
Frequency Range
136 to 174MHz
Modulation
Frequency modulation and external modulation
Output
–127dBm/0.1µV to greater than –7dBm/100mV
Input Impedance
50Ω
Operation Frequency
136 to 174MHz or more
Measurement Capability
Vicinity of 100W
Frequency Range
136 to 174MHz
Measuring Range
1 to 20V DC
Accuracy
High input impedance for minimum circuit loading
DC through 30MHz
Frequency Range
10Hz to 1000MHz
Frequency Stability
0.2ppm or less
20A
Frequency Range
50Hz to 10kHz
Voltage Range
1mV to 10V
Frequency Range
20Hz to 20kHz or more
Output
0 to 1V
Capability
3% or less at 1kHz
Input Level
50mV to 10Vrms
Approx. 4Ω, 10W or more
13.2V, approx. 20A (adjustable from 9 to 20V)
Useful if ammeter requipped
Test cable for microphone input (E30-3360-08)
MIC connector
(Front view)
8
1 : BLC
2 : PSB
3 : E
4 : PTT
5 : ME
6 : MIC
7 : HOOK
8 : CM
TK-760G/
Major Specifications
1
(
N
)
/762G/
(
N
)
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-762nTk-760nTk-762g

Table of Contents