Download Print this page

Concealed Installation - Toshiba RAS-M14GAV-E Installation Manual

Split type
Hide thumbs Also See for RAS-M14GAV-E:

Advertisement

Mounting directly on the fl oor.
1) Fix the leg of indoor unit on the fl oor with 2 mounting screws.
2) Fix the upper part of indoor unit on the wall with 4 mounting screws.
(Floor installation)
Slit
6 screw
(M4 x 25L)
NOTE
• In case the plinth is fi xed to the wall, please make sure to cut out the slit
on the left and right side of the main part.
Cut dot-line area
Installation on the wall
1) Fix the installation plate on the wall with 4 mounting screws.
2) Hook the indoor unit on the installation plate.
3) Fix the upper part of indoor unit on the wall with 4 mounting screws.
(Wall installation)
4 screw
(M4 x 25L)
4 screw
(M4 x 25L)
CAUTION
Make sure to fi x it at a designated position with the screws.
Failure may result the damage of piping by the turning over of a set.

Concealed Installation

The special method to install the indoor unit bury in the wall is shown here.
Please make sure to change to wall burying mode.
1. To switch to the wall burying mode
To switch to the wall burying mode, press and hold AIR OUTLET
SELECT button for 20 seconds.
- When the operation set up and 5 beep sounds. Then indication at
Temperature indicator will light up for 5 seconds.
- To cancel, press AIR OUTLET SELECT button for 20 seconds then, 5
beep sounds. Then indication at Temperature indicator will blinks for 5
seconds.
- To prevent dewfall, above plate angle should be narrow.
For prevent dewfall
Wall burying mode
EN
ES
2. Wall hole size
Wall hole size should be enough to keep the distance with indoor unit as
shown in the following fi gure.
FR
(Front view)
(Unit : mm)
(Side view)
70 or more
240 to 250
IT
800 or more
DE
PT
(700)
20 to 30
PL
Floor
CZ
50 or more
Indoor unit
50 or more
Floor
3. Installation using the supporting plate
RU
• To install into the existing wall hole, if it is impossible to keep 20-30 mm
of depth, use the supporting plate for securing the distance.
• Arrange the screw positions and supporting plate as shown in the
CR
fi gure.
• Be sure to switch to wall burying mode.
HU
(Rear screws potion)
(Side view)
(Field supply)
TR
NL
670
GR
SV
: Screw holes
(Unit : mm)
4. In case of lattice establishment
FI
• Follow the following fi gure, make sure to keep enough distance
between lattice, frame and wall.
• Be sure to switch to wall burying mode.
NO
• The lattice should be make of wood.
• Between the air inlet and outlet, should be devided with partition board.
• Be sure to establish the open part for RECEIVER.
DK
• The open part of lattice must be opens 70 % or more of the wall hole.
• The open part of lattice must be arranged uniformly.
(Top view)
(Unit : mm)
RO
BG
EE
Partition board
LV
SK
SI
Page 6

Hide quick links:

Advertisement

loading