Service Tools And Equipment; Changes And Features Overview; Abbreviations And Terms - Electrolux 30” GAS FREESTANDING RANGES Service Update Manual

Hide thumbs Also See for 30” GAS FREESTANDING RANGES:
Table of Contents

Advertisement

In addition to standard hand tools such as wrenches, screwdrivers, pliers, etc; the following instru-
ments are considered to be essential equipment for technicians servicing Electrolux cooking products.
Proper testing and diagnostic procedures are not possible without these tools.
Volt/ohmmeter - Must be capable of voltage measurement from 0 to 500 volts AC and
resistance measurements from 0 to 2 meg-ohms. This usually requires a meter that utilizes
a 9 volt battery. Either digital or analog meters are acceptable however most technicians fi nd
analog meters easier to use.
Clamp on amp meter - Should be capable of measuring from 0 to 60 amps.
Temperature Meter - Should be high quality with thermocouple or electronic
"K-type" test probe. Capable of temperature readings up to 1000 degrees Fahrenheit.
Additional instruments that a technician will need to have access to at various times include the
following:
Combustible gas leak detection meter.
U tube manometer or equivalent testing device for measuring LP and Natural gas line
pressure on gas ranges. Measurements must be in IWC (inches water column)
Carbon Monoxide (CO) detection meter capable of measuring from 0-1000 PPM.
Microwave Leak Detection Meter
For 2004/2005 some important new features and design changes have been
introduced into our gas freestanding ranges. Below is a list of the most signifi cant
changes.
• LARGER OVEN CAPACITY - 5.0 cu. ft.
• FRONT MOUNTED LEVELING FEET FOR GREATER STABILITY
• IMPROVED DOOR HINGE DESIGN FOR EASIER DOOR REMOVAL
• EXPANDED EOC FAULT CODES FOR MORE ACCURATE DIAGNOSIS
• NEW BODY SIDE DESIGN AND SERVICE PROCEDURE.
• DEEP SUMP COOKTOP WITH AVAILABLE FIVE BURNER DESIGN *
*
THESE FEATRUES NOT FOUND ON ALL MODELS
ABBREVIATIONS AND TERMS FOUND IN THIS MANUAL
EOC
= ELECTRONIC OVEN CONTROL
RTD
= RESISTANCE TEMPERATURE DEVICE (Temperature Sensor Probe)
GND
= GROUND
LED
= LIGHT EMITTING DIODE
BTU
= BRITISH THERMAL UNIT

SERVICE TOOLS AND EQUIPMENT

CHANGES AND FEATURES OVERVIEW

Page
5
P/N 316439221

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents