LEAK TEST
To check for leaks, complete the following steps:
CAUTION:
To avoid water or air pressure
dam-
age to softener
inner parts,
and to flush
pipe
chips or other residue
from the water pipes,
be
sure to do the following
steps exactly
as
instructed.
1. Fully open two cold, soft water faucets near the
softener.
2. Look at the pictures in Fig. 18 and 19 to deter-
mine your kind of bypass valve(s). Place bypass
valve(s) in "bypass" position. On a single valve,
slide the stem inward to bypass. On a three (3)
valve system, close the inlet and outlet valves and
open the bypass valve.
3. Fully open the house main water pipe shutoff
valve. Observe steady water flow from both open
faucets.
4. Place bypass valve(s) in SERVICE
EXACTLY as
follows: Keep soft water faucets open.
a. Single Bypass Valve: Slowly, slide pull the
valve stem outward toward service, pausing sev-
eral times to allow the softener to pressurize slow-
ly.
b. Three Valve Bypass:
Fully close the bypass
valve and open the outlet valve. Slowly, open the
inlet valve, pausing several times to allow the sof-
tener to pressurize slowly.
5. After about three minutes, open a hot water
faucet for about one minute, or until all air is
expelled, then close.
6. Close both cold water faucets.
7. Check your plumbing work for leaks and fix right
away if any are found. Be sure to observe previ-
ous caution
notes.
NOTE:
If this procedure
is performed
on a new
softener,
water coming
from the taps may initial-
ly be discolored.
This normally
occurs
the first
time water runs through
the resin bed.
The dis-
colored
water is not harmful,
and the discol-
oration
will not last more
than a few minutes.
HOUSE MAIN WATER
SHUTOFF
VALVES
Shu_
Water
¢--_%
Pressure Tank
Meter
Shutoff Valve
_
/
d"-
Well Pump
FIG. 17
SINGLE
BYPASS
Pull Stem Outward
For Service
_/_Push
Inward
For Bypass
Note: Stem may be installed
in either direction. The end
with writing should be pulled
out for service position.
FIG. 18
FOR SERVICE
Close bypass valve.
Open inlet & outlet
valves.
FOR BYPASS
Open bypass valve.
Close inlet & outlet
valves.
VALVE BYPASS
Outlet
Valve
/pass
Valve
Inlet
Valve
FIG. 19
Questions?
Call The Kenmore
Water Line 1-800-426-9345