[i:ii:ii:ii:_i: i :ii:_I SECTION
2 I_i:ii:ii:ii:_i:i:ii:_]
HOW YOUR WATER SOFTENER
WORKS
A. FACEPLATE
TIMER FEATURES
S
C
T
N
,JJJJJJJJJJJJJJJJ.
,JJJJ
JJJJJJJJJJ.
'dJ_idJdJdJdJ"
,JJ
JJJJJJJJJ.
,JJJ
JJJJJJJJJ.
,JJ
JJJJJJJJJ.
,JJJJJJJJJJJJJJJJ.
,JJJJJJJJJJJJJJJJ.
EXTRA
RECHARGE
Sometimes,
a manually
started
regeneration
(recharge)
may
be
desired,
or needed.
Two
exam-
ples are:
- You have used
more
water
than
usual
(guests
visiting)
and
you
may
run out of soft water
before
the next
timer
started
regenera-
tion.
- You did
not refill
the softener
with salt before
it was gone. After
you refill with
salt:
You can start a regeneration
right
away,
or you can set the timer
to
regenerate
at the next 2:00 AM (or
other
preset
recharge
time).
Do
the following.
RECHARGE
NOW
i°'I _
3,n_q _
_"
I'U!_-I
Press
the ON/OFF-HOLD
but-
i/
._C.A.G_
ton and hold until
*RECHARGE
..........
Serv and
Fill begin
to flash
in the
display.
Upon
reaching
fill the first cycle of regeneration,
the flash-
ing Serv goes off and Fill is on steady.
RECHARGE
continues
to flash.
This regeneration
will last for
about
2 hours.
After the 2 hours,
you will have soft
water
again.
*Note:
If the CLEAN
feature
is set to ON, a cleaning
back-
wash
(CLEAN
and Bkwsh or Rinse flashes
in the dis-
play, along
with
the minutes
of the clean
cycle re-
maining)
precedes
the recharge.
RECHARGE
TONIGHT
[ !°_
_:l-_n _-
Press and release
(do not hold) the
I i
R_C._G_TO_G.,
ON
/ OFF-HOLD
button.
RE-
CHARGE
TONIGHT
flashes
in the display,
and the
softener
begins
regeneration
at the next preset
re-
charge
time. Press and release
the ON/OFF-HOLD
button
once more
if you deride
to cancel the regen-
eration,
and RECHARGE
TONIGHT.
SALT MONITOR
SYSTEM
The face plate
timer has a low salt monitor
with an
indicator
light
to remind
you
to refill
the storage
tank
with salt. To set this monitor
system:
_1_
Lift the salt hole
cover
and level the salt in the
storage
tank.
ffi
The salt level
decal
on the brinewell
inside
the
tank, has numbers
from 0 to 8 (see drawing
be-
low). Observe
the number
the leveled
salt is at
or closest
to.
m
Now,
press
the SALT
LEVEL
ADJUST
button
until black bars display
up to the salt level num-
ber. For example,
the pictures
below
show
the
salt level at 6.
!!
Finall3_ set the level you want
the low salt indi-
cator light to come on. Press the SIGNAL
LIGHT
ADJUST
button
until a (_) shows
opposite
this
number.
In the example
below,
the
light
will
come on when
the stored
salt drops
to level 2. At
level 2, the storage
tank
is about
1/3 full. This is
the lowest
you should
allow the stored
salt level
to drop
to (see note on page
1-6).
_'_
If you wish to turn the salt monitor
off, press
the
SIGNAL
LIGHT
ADJUST
button
until
OFF
shows
above.
Note:
For
accurate
salt
monitor
operation,
always
use
nugget
or pellet
water
softener
salt. See page
1- 6.
salt
level
bars, salt
level
8
,
7
,
6
brinewell
decal
RECHARGE
TONIGHT
RECHARGE
NOW
indicator light
s_ ° w