Kenmore 420 Series Owner's Manual page 40

Water softeners with high performance valve
Table of Contents

Advertisement

POSITION SWITCH STATUS: With the valve in service,
or any of the recharge cycles, the switch indicator will
show open, while the valve is rotating from one position
to another, the indicator will show the switch closed. A
defect is probable if indications vary from this pattern.
NOTE: If the faceplate is left in a diagnostic display
(or a flashing display when setting times or hard-
ness), present time automatically returns if a button
is not pressed within 4 minutes. To return to the
diagnostic display, repeat step 1.
2. Press the RECHARGE button to advance the valve
to each position and observe the switch and position
indicators to verify component operation, or to possi-
bly isolate a defect.
3. Press Select once to move back to the Service Mode
screen. Move black bar to Set Model and press
Select. Verify the model code.
This code identifies the softener nominal capacity size.
If the wrong number shows, the softener will operate on
incorrect programming. Do the following as needed.
HF46 or HF47 does show - Press the SELECT button
until the normal operating display shows.
To change HF number - Press the UP or DOWN button
until either HF46 for Model 38426, or HF47 for Model
39426, shows in the display. Then, press the SELECT
button and reset the timer.
TIMER PWA REPLACEMENT
Be sure the valve is in service position when replac-
ing the timer PWA (observe valve cycle indicator). If
after installing and programming the replacement timer
PWA, the valve is not in service position, do the following
to assure correct cycle orientation, or timing, between the
faceplate and valve.
Use the MANUAL ADVANCE procedures with the
RECHARGE NOW button, advance through the recharge
cycles until the valve stops in service position, and
RECHARGE no longer flashes in the display.
NOTE: The valve motor may automatically drive through
several valve positions while searching for service. If an
error code occurs, unplug the transformer, then plug in
again.
40
Service Tech Information
Questions? Call The Kenmore Water Line 1-800-426-9345
Position Switch
Valve Outlet
Set Model :
HF46
CHANGE
b d
Set Model :
HF47
CHANGE
b d
Position markers
(Valve in service)
Motor
Sensor
Housing
Turbine
Turbine
Support
and Shaft
FIG. 64
SELECT
SELECT
FIG. 65
OUT
IN
MOTOR
FIG. 66

Advertisement