Kenmore POWER MISER 153.33062 Owner's Manual page 29

Ultra low nox gas water heater
Table of Contents

Advertisement

PROBLEM
POSSIBLE CAUSE(S)
CORRECTIVE
ACTION
DRIP FROM RELIEF VALVE
1.
Excessive water pressure
1.
Use a pressure reducing valve and relief
valve
2.
Closed water system
2.
See "Thermal Expansion"
THERMOSTAT
FAILS TO
1.
Non-functioning
thermostat
1.
Replace thermostat
SHUT OFF
2.
Improper calibration
2.
Replace thermostat
COMBUSTION
ODORS
1.
Insufficient
air
1.
Provide ventilation to water heater.
Check flue
way, flue baffle, and burner
2.
Water heater flue or vent system blocked.
2.
Clean, locate source and correct
3.
Heater installed in a confined area
3.
Provide fresh air ventilation
SMOKINGAND
CARBON
1.
Flammable vapor incident
1.
Call 1-800-4-MY-HOME ® (1-800-469-4663)
FORMATION (SOOTING)
CONDENSATION
1.
Temperature setting too low
1.
BURNER FLAME FLOATS
AND LIFTS OFF PORTS
1.
Orifice too large
2.
High gas pressure
3.
Water heater flue or vent system blocked.
4.
Cold drafts
5.
Dirty burner screen
Increase the temperature setting
1.
Replace with correct orifice
2.
Check with gas utility company
3.
Clean flue and burner-locate
source and
correct
4.
Locate source and correct
5.
Clean burner screen. See "Ultra Low
NOx Natural Gas Burner" section of this
manual.
FLAME BURNS AT ORIFICE
1.
Non-functioning
thermostat
1.
Replace thermostat
2.
Low gas pressure
2.
Check with gas utility company
3.
Non-functioning
burner
3.
Replace burner assembly
PILOT FLAME TOO SMALL
1.
Pilot line or orifice clogged
1.
Clean, locate source and correct
2.
Low gas pressure
2.
Check with gas utility company
3.
Dirty pilot
3.
Clean pilot
29