Kenmore POWER MISER 153.32636 Owner's Manual page 11

Kenmore water heater user manual
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Converting
the Lower
Element (cont'd)
2. The convertible
element is located
behind
the lower access
panel of the water heater.
Remove the two screws securing
the access panel, and remove panel.
5. Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
3. Remove the insulation block and pad.
6. The buss bar is labeled 5500 W. Place the buss bar over termi-
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3.
7. The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
4. Lower Element:
Lift out the tab as shown to unclip the ter-
minal cover from the thermostat.
The terminal
cover can be
removed from the thermostat.
Lift out tab to until
term hal cover from
_hermostat,
JAeKETli
TERHINALCOVER,
CLIPPED
TO THER-
\
MOSTAT
AT THIS
\
POINT
\
LOWER
THERHOSTAT
PLASTIC
TABS ON
BOTH
SIDES OF
TERHINAL
COVER
HOLD
IT iN
PLACE.
THERHOSTAT
/BRACKET
_TANK
ELEHENT
8. Tighten
terminals
2 and 3 to ensure proper electrical
connection.
&WARNING
Failure to tighten terminal
screws can cause a fire which
can result
in DEATH,
SERIOUS
BODILY
INJURY, OR
PROPERTY DAMAGE.
11

Hide quick links:

Advertisement

Table of Contents
loading