Product Specifications - Kenmore 305 Owner's Manual

Direct vent tankless water heaters 305 series 505 series natural/propane gas
Table of Contents

Advertisement

MODEL
Minimum gas consumption btu/h
Maximum gas consumption btu/h
305 Models
154.330040 & 154.330050
505 Models
154.330080 & 154.330090
15,000
180,000 Natural Gas
199,000 Natural Gas
180,000 Propane Gas
199,000 Propane Gas
Hot water capacity (Min - Max) *
0.6 - 7.5 GPM
0.6 - 9.4 GPM
(2.3 - 28.4 L/min)
(2.3 - 35.5 L/MIN)
Hot water capacity (45°F rise)
6.6 GPM (25.0 L/min)
7.4 GPM (28.0 L/min)
Default Temperature Setting (no controller)
1200 F (490 C)
Temperature
Controller Default Temperature
1040 F (400 C)
Setting
Maximum Temp Setting (Residential)
Selectable at 1200 F (490 C) or at 1400 F (600 C)
Minimum Temperature
Setting
980 F (370 C)
Weight
46 Ib (20.9 kg)
Efficiency Rating
83%
Noise Level
49 dB
Electrical
Normal
50 W
55 W
Consumption
Standby
2.0 W
Anti-Frost
Protection
100 W
By-Pass Control
Fixed
Electronic
Minimum Gas
Natural Gas
5.0 inch W.C.
Supply Pressure
Propane
8.0 inch W.C.
Maximum Gas
Natural Gas
10.5 inch W.C.
Supply Pressure
Propane
13.5 inch W.C.
Type of Appliance
Direct Vent, Temperature controlled
continuous flow gas hot water system
Operation
With Or Without Temperature
Controls, Mounted In Kitchen, Bathroom, Etc.
Approved Gas Type
Natural Gas Or Propane - Ensure Unit Matches Gas Type It's Being Installed On.
Connections
Gas Supply: 3/4" Mnpt, Cold Water Inlet: 3/4" Mnpt, Hot Water Outlet: 3/4"
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: Ac 120 Volts, 60hz. Temperature
Control: Dc 12 Volts (Digital)
Water Temperature Control
Simulation Feedforward And Feedback.
Water Supply Pressure
Minimum Water Pressure: 20 Psi (Recommended
30-80 Psi For Maximum Performance)
Maximum Water Supply Pressure
150 PSI
Temperature
Control Cable
Non-Polarized
Two Core Cable (Minimum 22 Awg)
Star Qualified
Yes
I
Yes
Energy
I
Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Specifications
are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed
is for the purpose of input adjustment.
305 & 505 Outdoor
Manual
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

505154.330040154.330050154.330080154.330090