Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Faimure to follow these instructions can result in death,
fire, or emectrical shock.
A 120-volt, 60-Hz., AC-only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is recommended
that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a
3 prong grounding
plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type
outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
GROUNDING
mNSTRUCTJONS
For a grounded,
cord-connected
washer:
This washer must be grounded, in the event of a maIfunction
or breakdown, grounding wiII reduce the risk of electrical
shock by providing a path of Ieast resistance for electric
current. This washer is equipped with a cord having an
equipment-grounding
conductor and a grounding pIug. The
plug must be plugged into an appropriate
outlet that is
properIy instalIed and grounded in accordance with all local
codes and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded.
Do not modify the piug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
For a permanently
connected
washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on
the appliance.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.