Administering the SPA400 and Voice Mail Service
Configuring a SPA400 to Interoperate with the SPA9000
STEP 5
STEP 6
STEP 7
STEP 8
STEP 9
STEP 10
STEP 11
SPA9000 Voice System Administration Guide
Downloaded from
www.Manualslib.com
•
Leave the Session Timer fields at the default values: Enabled with 0 seconds in
both Refresh Time fields.
Click Save Settings at the bottom of the page.
Click Setup tab > Voice.
Enter the following settings:
•
Preferred Codec: Select G.711u.
•
Packetization: Choose 30ms from the
•
VAD: Choose OFF from the
Click Save Settings at the bottom of the page.
To restart the SPA400, complete the following steps:
a. Click Administration tab > Reboot.
b. Click the Restart System button.
c. When the confirmation message appears, click OK. The SPA400 reboots.
Reboot OK
d. When the
If you are using this SPA400 as a PSTN gateway, connect the RJ11 cables from the
SPA400 to the wall outlet for PSTN access.
To verify your progress, perform the following tasks:
•
Click the Status tab, and confirm that the SIP registration status is Registered.
•
If you connected PSTN lines to the ports on the SPA400, confirm that you can
place an external call to the phone number that is associated with the PSTN
manuals search engine
Packetization
VAD
drop-down list for G.711U.
SPA400 Setup > Voice
. Go to Setup page? message appears, click OK.