3.
Slide Separator rollers (2 rollers, left and right) away from each other
along the shafts for removal as shown below.
⇒ The shaft will be locked in outer position and stays there.
4.
Remove the rollers from their shafts.
Remove both, the left and the right rollers.
5.
Put the new rollers (2 rollers, left and right) on the shafts.
Align the screw with the groove on the Separation roller to put the roller on the shaft.
Screw
Separator roller
Groove
5.5 Replacing the Separator Rollers
Separator roller
Shaft
Shaft