Main Battery - Toshiba PORTEGE A200 series Maintenance Manual

Personal computer
Hide thumbs Also See for PORTEGE A200 series:
Table of Contents

Advertisement

2 Troubleshooting Procedures
? DC power supply (AC adapter)
Error code
10h
11h
12h
13h
14h

? Main battery

Error code
21h
22h
23h
24h
25h
? S3V output
Error code
40h
45h
? 1R5-C1V output
Error code
50h
51h
52h
53h
54h
55h
2-10
AC Adapter output voltage is over 16.5V.
Commondock output voltage is over 16.5V.
Current from the DC power supply is over 6.05A.
Current from the DC power supply is over 0.5A when there is no load.
Abnormal current has been sensed 0[A].
Main battery charge current is over 6.05A.
Main battery discharge current is over 0.5A when there is no load.
Main battery charge current is over 3.1A when AC adapter is not
connected.
Abnormal current has been sensed 0[A].
Main battery charge current is over 0.3A.
S3V voltage is 3.14V or less when the computer is powered on/off.
S3V voltage is 3.14V or less at power-on. (CV support)
1R5-C1V voltage is over 1.8V when the computer is powered on/off.
1R5-C1V voltage is 1.275V or less when the computer is powered on.
1R5-C1V voltage is 1.275V or less at power-on.
1R5-C1V voltage is 1.275V or less while the computer is suspended.
1R5-C1V voltage is abnormal during shutdown. (CV support)
1R5-C1V voltage is 1.275V or less when the computer is booting up.
(CV support)
2.3 Power Supply Troubleshooting
Meaning
Meaning
Meaning
Meaning
PORTEGE A200 Maintenance Manual (960-499)