57 electrolux normal sounds

Normal sounds

2
3
1
High pitched chatter
Today's high efficiency compressors may have a high pitched chatter during
the cooling cycle.
Sound of rushing air
2
At the front of the unit, you may hear the sound of rushing air being moved
by the fan.
Gurgle/Hiss
3
"Gurgling or hissing" noise may be heard due to refrigerant passing through
evaporator during normal operation.
Vibration
4
Unit may vibrate and make noise because of poor wall or window
construction or incorrect installation.
Pinging or Swishing
5
Droplets of water hitting condenser during normal operation may cause
"pinging or swishing" sounds.
1
4
5

Solutions for problems

Before calling for service, review this list. It may save you time and expense.
This list includes common occurrences that are not the result of defective
workmanship or materials in this appliance.
Problem
Solution
Air conditioner will not
1. Wall plug disconnected. Push plug firmly into wall
operate.
outlet.
2. Plug Current Device Tripped. Press the RESET
button.
3. House fuse blown or circuit breaker tripped.
Replace fuse with time delay type or reset circuit
breaker.
4. Control is OFF. Turn Control ON and set to
desired setting.
Air from unit does not feel
1. Room temperature below 60°F (16°C). Cooling
cold enough.
may not occur until room temperature rises above
60°F (16°C).
2. Temperature sensing element touching cold coil,
located behind air filter. Straighten away from coil.
3. Reset to a lower temperature.
4. Compressor shut-off by changing modes. Wait
approximately 3 minutes and listen for
compressor to restart when set in the COOL
mode.
Air conditioner cooling, but
1. Outdoor temperature below 60 O F (16 O C). To
room is too warm - ice
defrost the coil, set FAN ONLY mode.
forming on cooling coil
2. Air filter may be dirty. Clean filter. Refer to Care
behind decorative front.
and Cleaning section. To defrost, set to FAN
ONLY mode.
3. Temperature is set too low for night-time cooling.
To defrost the coil, set to FAN ONLY mode. Then,
set temperature to a higher setting.
solutions for problems electrolux 58