AIR INDUCTION SYSTEM
EAS00510
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
_hoses
Loose connection ! Connect properly.
Cracks/damage ! Replace.
_pipes
Cracks/damage ! Replace.
2. Check:
_fibre reed 1
_fibre reed stopper
_reed valve seat
Cracks/damage ! Replace the reed valve.
3. Measure:
_fibre reed bending limit a
Out of specification ! Replace the reed
valve.
Fibre reed bending limit
0.2 mm (0.008 in)
1 Surface plate
4. Check:
_air cutoff valve
Cracks/damage ! Replace.
7-16
CARB