Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
aii electrical
connections.
Failure to do so can result in death, fire, or
electrical
shock.
1. Disconnect
power.
3. Install strain relief.
2. Remove the hold-down screw and terminal block cover.
Style 1: Power supply cord strain relief
E
F
AB
C
D
A. Terminal block cover
B. Hold-down
screw
C. External ground conductor
screw
D. Center, silver-colored
terminal block screw
E. Neutral ground wire
F. Hole below terminal block opening
Remove the screws from a s/4" (1.9 cm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down,
and hold in place. Tighten strain relief screws just enough to
hold the two clamp sections together.
/ t
........................................... C
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down