1. Safety Precautions Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. ...
Page 4
WARNING 19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc). 20.
2. Specification Indoor CS-C7MKP-7 CS-C9MKP-7 Model Outdoor CU-C7MKP-7 CU-C9MKP-7 Performance Test Condition NEW JIS NEW JIS Phase, Hz Single, 50 Single, 50 Power Supply 2.00 2.05 2.65 2.70 Capacity BTU/h 6820 6990 9040 9210 kJ/h 7200 7380 9540 9720 Running Current Input Power 3.39...
Indoor CS-C18MKP-7 CS-C24MKP-7 Model Outdoor CU-C18MKP-7 CU-C24MKP-7 Performance Test Condition NEW JIS NEW JIS Phase, Hz Single, 50 Single, 50 Power Supply 5.40 5.40 7.03 7.03 Capacity BTU/h 18400 18400 24000 24000 kJ/h 19440 19440 25310 25310 Running Current 11.0 11.1 Input Power 1.75k...
Page 10
Control Device Capillary Tube Capillary Tube Refrigeration Refrigerant Oil ATMOS M60 or Suniso 4GDID (450) ATMOS M60 or Suniso 4GDID (700) Cycle Refrigerant Type g (oz) R22, 950 (33.5) R22, 1.20k (42.4) Height(I/D / O/D) mm (inch) 290 (11-7/16) 540 (21-9/32) 290 (11-7/16) 750 (29-17/32) Dimension...
Features E-ion Air Purifying System with Patrol Sensor Active e-ions are released to catch dust particles and bring them back the large positively charged filter. Patrol Sensor color changes to indicate the dirt level in the air Long Installation Piping CS/CU-C7MK, CS/CU-C9MK, long piping up to 10 meters.
8. Wiring Connection Diagram CS-C7MKP-7 CU-C7MKP-7 CS-C9MKP-7 CU-C9MKP-7 CS-C12MKP-7 CU-C12MKP-7 Resistance of Indoor Fan Motor Windings MODEL CS-C7MKP-7 / CS-C9MKP-7 / CS-C12MKP-7 CONNECTION CWA921434 BLUE-YELLOW 351.3 YELLOW-RED 343.9 Note: Resistance at 25°C of ambient temperature. Resistance of Outdoor Fan Motor Windings...
CS-C18MKP-7 CU-C18MKP-7 Resistance of Outdoor Fan Motor Windings Resistance of Compressor Windings MODEL CU-C18MKP-7 MODEL CU-C18MKP-7 CONNECTION CWA951705 CONNECTION 2KS314D5BA06 BLUE-YELLOW 223.0 1.853 YELLOW-RED 255.6 4.879 Note: Resistance at 25°C of ambient temperature. Note: Resistance at 20°C of ambient temperature.
CS-C24MKP-7 CU-C24MKP-7 Resistance of Outdoor Fan Motor Windings Resistance of Compressor Windings MODEL CU-C24MKP-7 MODEL CU-C24MKP-7 CONNECTION CWA951383J CONNECTION 2JS438D3CB04 BLUE-YELLOW 116 1.121 YELLOW-ORANGE 136 2.535 YELLOW-RED 103 Note: Resistance at 20°C of ambient temperature. Note: Resistance at 25°C of ambient temperature.
11. Installation Instruction 11.1 Select the Best Location 11.1.3 Indoor/Outdoor Unit Installation 11.1.1 Indoor Unit Diagram Do not install the unit in excessive oil fume area such as kitchen, workshop and etc. There should not be any heat source or steam near the unit.
11.2 Indoor Unit 11.2.1 How to Fix Installation Plate The mounting wall shall be strong and solid enough to prevent if from the vibration. The center of installation plate should be at more than c at right and left of the wall. The distance from installation plate edge to ceiling should more than d.
Page 32
11.2.3 Indoor Unit Installation 11.2.3.1 For the right rear piping 11.2.3.2 For the right and right bottom piping 11.2.3.3 For the embedded piping (This can be used for left rear piping and bottom piping also.
Page 33
11.2.4 Connect the Cable to the Indoor Unit The inside and outside connection cable can be connected without removing the front grille. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 1.5 mm (3/4~1.5HP) or 3 x 2.5 mm (2.0~2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord.
Page 34
11.2.5 Wire Stripping And Connecting Requirement 11.2.5.1 Cutting and flaring the piping Please cut using pipe cutter and then remove the burrs. Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe.
11.3 Outdoor Unit 11.3.1 Install the Outdoor Unit After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram. Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm). When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand firmly with bolt or nails.
11.3.3 Evacuation of the Equipment Connect a charging hose with a push pin to the Low side of a charging set and the service port of the 3-way valve. Be sure to connect the end of the charging hose with the push pin to the service port. Connect the center hose of the charging set to a vacuum pump.
Page 37
11.3.4 Connect the cable to the Outdoor Unit Remove the control board cover from the unit by loosening the screw. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 1.5mm (3/4~1.5HP) or 3 x 2.5mm (2.0~2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord.
The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. During cooling operation, the compressor will stop and restart as shown in figure below: 12.1.1 Cooling Operation Time Diagram (For CS-C7MKP-7 CU-C7MKP-7, CS-C9MKP-7 CU-C9MKP-7 and CS-C12MKP-7 CU-C12MKP-7)
Page 39
12.1.2 Cooling Operation Time Diagram (For CS-C18MKP-7 CU-C18MKP-7 and CS-C24MKP-7 CU-C24MKP-7)
However after 3 minutes of compressor off, during Soft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point. 12.2.1 Soft Dry Operation Time Diagram (For CS-C7MKP-7 CU-C7MKP-7, CS-C9MKP-7 CU-C9MKP-7 and CS-C12MKP-7 CU-C12MKP-7)
Page 41
12.2.2 Soft Dry Operation Time Diagram (For CS-C18MKP-7 CU-C18MKP-7 and CS-C24MKP-7 CU-C24MKP-7)
12.3 Automatic Operation Automatic operation can be set using remote control. This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature. After judged the temperature, the operation mode is determined by referring to the below standard. Cooling Operation Intake Air 23°C...
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. Fan speed rotates in the range of Hi and Me (For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7). Fan speed rotates in the range of Hi, Me and Lo- (For CS-C18MKP-7 and CS-C24MKP-7).
Page 44
For CS-C18MKP-7 and CS-C24MKP-7 Stop Manual Normal Auto Hi-90 Manual Me-90 Quiet CLo-90 Auto Hi-90 Me-90 Manual Powerful Auto Manual Normal Auto Manual Quiet Auto Auto Fan Speed during cooling operation: Indoor fan will rotate alternately between off and on as shown in below diagram. At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing purpose.
During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the louver will stop swinging. For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7 Horizontal Upper limit for cooling mode and soft dry mode/11°...
Page 46
The louver can be adjusted by pressing the button to the desired louver position. When stop operation using the remote control, the discharge vent is reset, and stop at the closing position. For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7 Horizontal Upper limit for cooling mode and 11°...
During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the vane will stop swinging and rest at face front position. For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7 For CS-C18MKP-7 and CS-C24MKP-7 12.7.2 Manual Control...
12.8 Powerful Operation To achieve the setting temperature quickly. When powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present setting temperature (Lower temperature limit: 16°C). This operation automatically running under Shi fan speed (Cooling), Lo- Fan Speed (Soft Dry) is applicable for C7MKP-7, C9MKP-7 and C12MKP-7 only.
RPM control during Hi & Me cool Auto Fan Speed Quiet operation stops when: Quiet button is pressed again. Stopped by OFF/ON operation button. Timer OFF activates. Operation mode button is changed. 12.10 Timer Control 12.10.1 ON Timer ...
12.13 Patrol Operation To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation Patrol operation starts condition When the unit operation is started with “OFF/ON” button When the unit stops, “Patrol” operation is selected, Patrol individual operation will start. During cooling only operation, “Patrol”...
Page 51
Patrol Sensor Control First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is monitored. The Air Dirtiness level is set to Clean, Patrol LED turns blue color. After that, Patrol sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air.
Page 52
Airflow direction (Horizontal, Vertical) Control During any operation mode combines with Patrol operation, airflow direction follows respective operation mode. During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no signal is sent to air conditioner, and no change on LCD display. During Patrol individual operation if e-ion stops, Airflow direction louver closed.
Page 53
Patrol Operation Demo Mode Patrol Operation Demo Mode start condition Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal setting mode. Press “Timer Decrement" button to select “Pt demo”. ...
12.14 E-ion operation This operation provides clean air by producing negative ions to attract dust captured at the positively charged active e-ion filters. e-ion operation start condition During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation mode + e-ion operation) starts.
Page 55
e-ion Check Mode e-ion abnormality check mode Purpose is to improve sensor serviceability when sensor is malfunction. (1) Control starting condition When all of the conditions are formed Not in Patrol Demo mode. e-ion operation ON. When e-ion check mode signal is received;...
Page 56
Error Detection Control When e-ion indicator blink, it indicates error listed below: Active e-ion Air Purifying system PCB main connector open: Judgment Method During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main connector to PCB is opened. ...
12.15 AUTO COMFORT and ECO NAVI Operation Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide comfort environment while maintain the energy saving level.
Page 58
12.15.1 Signal Detection Human Activity sensor will turns on according to infrared sensors signal detection. Signal detection Possible detected human Human Activity Indicator position area Sensor 1 Sensor 2 Left Center Right A & C B & C A & C A, B &...
Page 59
12.15.7 Setting Position Judgment According to installation position when there is only one activity area detected, the horizontal airflow direction louver position is fixed according to chart below: Horizontal airflow direction louver position Target area Left installation Center installation Right installation ...
Page 60
12.15.9 ECO NAVI and AUTO COMF Demo Mode To enable ECO DEMO mode: To disable ECO Demo MODE: Transmit ECO Demo signal again. Transmit Patrol Demo signal. Operation details Infrared sensor Human Activity Sensor Vane position Fan speed Sensor 1 Sensor 2 Left...
Page 61
12.15.10 Infrared Sensor Abnormality Abnormality detection: Connector disconnection / Wire cut abnormality Sensor judge Hi level continuously for 25 seconds Circuit abnormality 70 seconds after power ON, if infrared sensor judge Lo level continuously for 25 seconds ...
13. Protection Control 13.1 Restart Control (Time Delay Safety Control) When the thermo-off temperature (temperature which compressor stops to operate) is reach during:- Cooling operation – the compressor stops for 3 minutes (minimum) before resume operation. Soft Dry operation – the compressor stops for 6 minutes (minimum) before resume operation. ...
13.5 Freeze Prevention Control To protect indoor heat exchanger from freezing and to prevent higher volume of refrigerant in liquid form return to compressor. This control will activate when temperature of indoor heat exchanger falls below 2°C continuously for more than 4 minutes and compressor turn off.
13.7 Dew Prevention Control To prevent dew formation at indoor unit discharge area. This control starts if: Cooling mode or Quiet mode is activated. Remote Control setting temperature is less than 25°C. Fan speed is at CLo or QLo. Room temperature is constant (±1°C) for 30 minutes.
14. Servicing Mode 14.1 Auto OFF/ON Button Auto OFF/ON Auto OFF/ON Auto OFF/ON Button Pressed Button Pressed Button Pressed 5 sec 5 sec Auto Operation Test Run Operation Stop Various Setting Mode Stop (Forced Cooling Operation) “Beep” 2 x “Beep” AUTO OPERATION MODE The Auto Operation will be activated immediately once the Auto OFF/ON button is pressed.
14.2 Remote Control Button 14.2.1 SET Button To check current remote control transmission code and store the transmission code to EEPROM: Press “Set” button continuously for 10 seconds by using pointer. Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code change. ...
15. Troubleshooting Guide 15.1 Refrigeration cycle system In order to diagnose malfunctions, ensure the air conditioner is free Normal Pressure and Outlet Air Temperature (Standard) Gas Pressure Outlet air from electrical problems before inspecting the refrigeration cycle. Temperature Such problems include insufficient insulation, problem with the (kg/cm (°C) power source, malfunction of a compressor and a fan.
15.1.1 Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Condition of the air conditioner Low Pressure High Pressure Electric current during operation Insufficient refrigerant Ô Ô Ô (gas leakage) Clogged capillary tube or Ô...
High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 16.1 CS-C7MKP-7 CS-C9MKP-7 CS-C12MKP-7 16.1.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 16.1.1.1...
WARNING High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 16.2 CS-C18MKP-7 CS-C24MKP-7 16.2.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures 16.2.1.1 To remove front grille...
Page 74
16.2.1.3 To remove power electronic controller Figure 13 Figure 14 Figure 15...
Page 75
16.2.1.4 To remove discharge grille Figure 16 16.2.1.5 To remove control board Figure 17 16.2.1.6 To remove cross flow fan and indoor fan motor Figure 18...
18. Exploded View and Replacement Parts List 18.1 Indoor Unit 18.1.1 CS-C7MKP-7 CS-C9MKP-7 CS-C12MKP-7 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 89
REF. PART NAME & DESCRIPTION CS-C7MKP-7 CS-C9MKP-7 CS-C12MKP-7 REMARK CHASSIS COMPLETE CWD50C1599 FAN MOTOR CWA921434 CROSS FLOW FAN COMPLETE CWH02C1076 BEARING ASS’Y CWH64K007 SCREW - CROSS FLOW FAN CWH551146 GENERATOR COMPLETE CWH94C0031 CWH94C0028 EVAPORATOR CWB30C3399 CWB30C3247 FLARE NUT (LIQUID) CWT251026...
Page 90
OPERATING INSTRUCTION CWF568100 INSTALLATION INSTRUCTION CWF614303 INSTALLATION INSTRUCTION CWF614532 POWER SUPPLY CORD COMPLETE CWA20C2901 COVER FOR RECEIVER (UPPER) CWD933022 COVER FOR RECEIVER (BOTTOM) CWD933209 (Note) All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488). “O” marked parts are recommended to be kept in stock.
Page 91
18.1.2 CS-C18MKP-7 CS-C24MKP-7 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 92
REF. PART NAME & DESCRIPTION CS-C18MKP-7 CS-C24MKP-7 REMARK CHASSIS COMPLETE CWD50C1623 FAN MOTOR ARW7628AC ARW7627AC CROSS FLOW FAN COMPLETE CWH02C1077 BEARING ASS’Y CWH64K007 SCREW - CROSS FLOW FAN CWH551146 ION GENERATOR CWH94C0028 EVAPORATOR CWB30C2807 CWB30C2808 FLARE NUT (LIQUID) CWT251026 FLARE NUT (GAS) CWT251062 CWT251036 E-ION AIR PURIFYING SYSTEM...
Page 93
BAG COMPLETE - INSTALLATION SCREW CWH82C1705 INSTALLATION PLATE CWH361098 FULCRUM CWH621103 OPERATING INSTRUCTION CWF568100 INSTALLATION INSTRUCTION CWF614303 INSTALLATION INSTRUCTION CWF614532 POWER SUPPLY CORD COMPLETE CWA20C2905 CWA20C2904 (Note) All parts are supplied from PHAAM, Malaysia (Vendor Code: 00029488). “O” marked parts are recommended to be kept in stock.
18.2 Outdoor Unit 18.2.1 CU-C7MKP-7 CU-C9MKP-7 CU-C12MKP-7 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 95
REF. PART NAME & DESCRIPTION CU-C7MKP-7 CU-C9MKP-7 CU-C12MKP-7 REMARK CHASSIS ASS’Y CWD50K2107 SOUND PROOF MATERIAL CWG302254 FAN MOTOR BRACKET CWD541069 CWD541074 SCREW - FAN MOTOR BRACKET CWH551217 FAN MOTOR CWA951673 CWA951691 SCREW - FAN MOTOR MOUNT CWH55252J CWH55406J PROPELLER FAN ASS’Y CWH03K1020 NUT - PROPELLER FAN CWH56053J...
Page 96
18.2.2 CU-C18MKP-7 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 97
REF. PART NAME & DESCRIPTION CU-C18MKP-7 REMARK CHASSIS ASS’Y CWD50K2088 SOUND PROOF MATERIAL CWG302442 FAN MOTOR BRACKET CWD541030 SCREW - FAN MOTOR BRACKET CWH551217 FAN MOTOR CWA951705 SCREW - FAN MOTOR MOUNT CWH55252J PROPELLER FAN ASS’Y CWH03K1010 NUT - PROPELLER FAN CWH56053J COMPRESSOR 2KS314D5BA06...
Page 98
18.2.3 CU-C24MKP-7 Note The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 99
REF. PART NAME & DESCRIPTION CU-C24MKP-7 REMARK CHASSIS ASS’Y CWD50K2100 FAN MOTOR BRACKET CWD541065 SCREW - FAN MOTOR BRACKET CWH551217 FAN MOTOR CWA951383J SCREW - FAN MOTOR MOUNT CWH55252J PROPELLER FAN ASS’Y CWH03K1017 NUT - PROPELLER FAN CWH561038J COMPRESSOR 2JS438D3CB04 PACKING CWB81043 ANTI - VIBRATION BUSHING...