Pressure Relief Valve - Kärcher ICC 1 S D Service Manual

Hide thumbs Also See for ICC 1 S D:
Table of Contents

Advertisement

ICC 1 S D
Hydraulic System – Pressure relief valve
Side console, view from right
Side console, view from left, seat tilted forward
Side console raised, adjusting pressure relief valve
Basic Settings and Service Procedures
Adjusting pressure relief valve
The pressure relief valve is used to adjust the
working pressure for functions such as "Raise /
Lower Debris Container" and raising / lowering
side brushes and vacuum intake.
Remove mounting screws (2x), see arrows
Tilt up seat.
Remove mounting screws (2x), see arrows.
Lift side console approx. 30 mm until pressure
relief valve can be seen.
Note:
As a prerequisite, the unit must have been
prepared as described on page 50.
Loosen lock nut (1).
Using Allen wrench (3), adjust pressure by
turning screw (2).
Turning clockwise increases pressure.
Turning counter-clockwise reduces
pressure.
For nominal value, refer to Specifications.
1
Lock nut
2
Adjusting screw
3
Allen wrench, 5 mm size
4
Side console, raised
51