Refrigerating Cycle
12. Condenser
CAUTION: Discharge the refrigerant
system using a Freon
System. If there is no valve to attach the
recovery system, install one (such as a
WATCO A-1) before venting the Freon
Leave the valve in place after servicing
the system.
1. Remove the cabinet. (Refer to section 2)
2. Remove the 4 screws that fasten the
brace.(Refer to section 4)
3. Remove the 5 screws that fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the con-
denser connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Figure 23)
13. Evaporator
1. Remove the control box.(Refer to section 3)
2. Remove the air guide upper. (Refer to section 4)
3. Remove the 2 screws that fasten the evapora-
tor.
4. Move the evaporator sideways carefully.
(Refer to section 4)
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evapo-
rator connections.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Figure 24)
14. Capillary Tube
1. Remove the cabinet. (Refer to section s2)
2. After discharging the refrigerant completely,
unbraze the interconnecting tube at the capillary
tube.(See caution above)
TM
Recovery
TM
.
3. Remove the capillary tube.
4. Re-install the components by referring to notes.
Disassembly
Figure 23
Figure 24
Service Manual 17