Haier HDY-D70-E Service Manual page 20

Condenser tumber dryer
Hide thumbs Also See for HDY-D70-E:
Table of Contents

Advertisement

Code
Error message: The temperature tested by NTC does not change.
Check whether the heater is short
circuit or cut off
N
Chek whether the lint screen is
blocked
N
Check whether the NTC is
short circuit or cut off ( the
resistance number of NTC
is nearby 10K )
Code
Error message: The laundry not dried.
Consult the users to see if there
are wrong operations
N
Check whether the lint screen
is blocked
N
Check whether the heater can
work normally
Code
Error message: NTC is short circuit or cut out
Check if the NTC terminals are
inserted properly
Y
Condenser Tumber Dryer
NTC connection
HDY-C70-E/-F
Replace the heater which
Y
can not work
Y
clear the lint screen
Y
Replace the NTC
1 Do not put the clothes
dripping water into drum
2 Do not overload the dryer
3 Avoid adding clothes into
Y
the drum when the drying
cycle is nearly finished
Clear the lint screen
Y
Replace the heater which
N
can not work
Insert the NTC terminals
N
properly