Filling The Condensate Trap - Bosch Integra 500 Installation Manual

Temperature modulated with electronic ignition
Hide thumbs Also See for Integra 500:
Table of Contents

Advertisement

3.12 Filling the condensate trap

The condensate trap can be filled before or after
connecting the vent pipe.
Filling the condensate trap before vent pipe
installation
Danger: Prior to initial start up, and
after appliance has been out of use for a
long time or after cleaning the sifon,
make sure that you fill the condensate
trap with water. This is to prevent
dangerous exhaust gases from entering
the building.
B Fill the condensate trap by pouring approx.14 oz.
(400ml) of water into the exhaust accessory on the
top of the appliance, see Fig. 30.
Fig. 30 Filling the condensate trap at start up
Filling the condensate trap after vent pipe
installation
After appliance has been out of use for a long time or
after cleaning siphon, refill the condensate trap with
water.
Please proceed as follows:
B Remove front cover, see Fig. 4, page 6.
B Open the four clips and remove the combustion
cover, see Fig. 5, page 6.
B Remove the clip and disconnect the drain tube, see
Fig. 31.
Fig. 31 Disconnect drain tube
6 720 680 226
B Fill the condensate trap by pouring approx.14 oz.
(400ml) of water into the top of the drain tube. To
avoid damage to the appliance use a funnel in this
operation, see Fig. 32, page 27.
Fig. 32 Filling the condensate trap after installation
B Loosen the three screws of the control unit.
Fig. 33
B Put the control unit in service position by engaging its
tabs with the holes in the bottom horizontal sheet
metal, see Fig. 34.
B Check water level in the condensate trap.
Fig. 34 Water level in condensate trap
B After filling reassemble all parts in reverse order.
Installation instructions
27

Advertisement

Table of Contents
loading

Table of Contents