Alliance Laundry Systems 50 Pound Series Installation Manual
Alliance Laundry Systems 50 Pound Series Installation Manual

Alliance Laundry Systems 50 Pound Series Installation Manual

Drying tumblers
Table of Contents

Advertisement

Quick Links

Drying Tumblers
NOTA: Para bajar una
copia de estas
instrucciones en
español, visite
www.comlaundry.com.
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
50 Pound Capacity
75 Pound Capacity
Refer to Page 4 for Model Identification
www.comlaundry.com
TMB795C
TMB795C
Part No. M414905R10
August 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 50 Pound Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alliance Laundry Systems 50 Pound Series

  • Page 1 Drying Tumblers 50 Pound Capacity 75 Pound Capacity Refer to Page 4 for Model Identification NOTA: Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com. TMB795C TMB795C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) Part No.
  • Page 3 These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumbler for customer use. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 4: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414905...
  • Page 5 Gas and Electric Tumblers............... 55 Loading Door Switch................57 Loading Door Catch ................57 Drive Belt....................57 Nonreversing Models............... 57 Reversing Models ................57 Removing Tumbler from Service ............60 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 6: Introduction

    GU075N UT075N ST075S HA075L UTF75L ST075T HA075N UTF75N SU075S HT075D UU075L SU075T HT075L UU075N UT075S HT075N YT075L UT075T HU075L YT075N UU075S Suffixes listed on the following page. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 7 ZX –NetMaster network, prep for coin CX –prep for coin QT –dual digital timer ZY –NetMaster network, prep for card CY –prep for card R3 –reversing DX4 OPL M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 8: Customer Service

    Kilograms Inches W.C. 0.036 Pounds/sq. inch Boiler Horsepower 33,479 Btu/hr. Inches W.C. 0.249 Boiler Horsepower 34.5 lbs. steam/hr. lb/inch (psi) 6.895 0.471 liters/second 28.32 Liters 3414 Btu/hr. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 9: Safety Information

    “NOTE”) are followed by specific instructions. IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 10: Save These Instructions

    12. Always clean the lint filter daily. 13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 11 28. DO NOT operate the tumbler if it is smoking, W055 grinding, has missing or broken parts. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 12: Specifications And Dimensions

    Kilowatts (kW) 30 kW (other voltages) Steam Models 3/4 in. NPT 3/4 in. NPT Steam Connection Steam Coil Rating: Boiler Horsepower (Btu/hr) (177,500) (210,300) N/A = Not Applicable M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 13: Cabinet Dimensions

    * A, H, S and U models prior to Serial No. 0308001307 and all other models. ** A, H, N, S and U models after Serial No. 0308001307. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 14: Exhaust Outlet Locations

    Models 5.375 in. 8 in. 13.375 in. 50/75 Pound (137 mm) (203 mm) (340 mm) 6.5 in. 10 in. 6.5 in. (165 mm) (254 mm) (165 mm) M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 15: Gas Connection Locations

    (394 mm) (1670 mm) 1/2 in. NPT 15.75 in. 65.75 in. 75 Pound (400 mm) (1670 mm) 3/4 in. NPT 15.75 in. 65.75 in. (400 mm) (1670 mm) M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 16: Electrical Connection Locations

    9.5 in. 63.5 in. Gas and Steam (241 mm) (1613 mm) 19 in. 64 in. Electric (483 mm) (1626 mm) NOTE: These figures are approximate dimensions only. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 17: Steam Connection Locations

    Steam Connection Locations TMB814N TMB814N Models Diameter 3/4 in. NPT 15.25 in. 72.75 in. 7.5 in. 64.75 in. 50/75 Pound (387 mm) (1848 mm) (190 mm) (1645 mm) M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 18: Installation

    Due to varied from combustible materials, gasoline and other requirements, applicable local codes should be flammable vapors and liquids. thoroughly understood and all pre-installation work arranged for accordingly. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 19: Location Requirements

    24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed Figure 1 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 20: Position And Level The Tumbler

    The unit must rest firmly on floor so weight of tumbler is evenly distributed. TMB2014K TMB2014K Loading Door Front Panel Access Panel Cylinder T483I Lint Panel T483I Figure 3 Figure 2 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 21 9. Disconnect the motor harness(s). 16. Refer to the appropriate troubleshooting manual, installation manual and wiring diagram to reassemble and install the tumbler correctly. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 22: To Reverse The Loading Door

    IMPORTANT: Support door and hinge assembly Lint Panel securely to prevent it from dropping once side Front Panel screws are removed from door hinge lug. Control Panel Figure 6 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 23 Original Switch Location TMB1995N Lint Panel Switch Harness Plug Wire Ties Switch Original Plug Location Side Screw Top Panel Door Hinge Lug Door Assembly Figure 8 Figure 7 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 24 Wire ties must be used to secure harnesses. Wire ties (Part No. 55881) can be ordered from RSPC. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 25: Before Placing Tumbler Into Service

    Removing Tumbler from Service section. gas shut-off valve is in the ON position and that the gas service is properly connected. If condition still persists, remove tumbler from service. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 26: Required For Ce Models Only

    L.P. Gas configurations that must be regulated. For L.P. Gas, third family B/P at 50 mbar, order Regulated Natural Gas machines and convert according to Table 1. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 27 N/A = Part no longer available. ** For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model, M411334 regulator spring kit and burner orifice(s). M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 28: Basic Configuration

    No. M400763 (Johnson Part No. Y71AA-5C). NOTE: This kit does not contain any burner orifices. c. Replace burner orifice(s) as per Table 1. d. Commission tumbler for use. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 29 5. Commission tumbler for use. nut near gas valve. Remove the burner orifice(s) from spud holder. Refer to Figure 12. NOTE: Blank burner orifices are Part No. M400995. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 30 Remove regulator cap and adjust regulator screw until the burner orifice pressure per applicable table is achieved. Replace Figure 13 regulator cap. Refer to Figure 12. 5. Commission tumbler for use. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 31: Exhaust Requirements

    If it is necessary to duct make-up air to tumbler(s), increase area of duct work by 25% to compensate for restrictions in air movement. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 32: Individual Venting

    1200 feet per minute Figure 14 (366 m/min.) to ensure that lint remains airborne. If 1200 feet per minute cannot be maintained, schedule monthly inspections and cleaning of the ductwork. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 33 Consult your local building code for regulations which NOTE: Where exhaust duct pierces a combustible may also apply. wall or ceiling, the opening must be sized per local codes. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 34 Outlet duct diameter for one battery combustible wall or ceiling, the opening Outlet duct diameter for two batteries MUST be sized per local codes. 45° typical Figure 16 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 35 40 in. (1016 mm) 35 in. (889 mm) 50 in. (1270 mm) 30 in. (762 mm) 42 in. (1067 mm) 36 in. (914 mm) 51 in. (1295 mm) Table 3 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 36: Gas Requirements

    CE GASES refers to Installing CE Gas Drying and Australian Gas Association/Australian ● Tumblers section, the above data does not apply to the L.P. Gas Association requirements in Australia. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 37 Gas Supply Piping System W635 Gas “T” Fitting 6 in. (152 mm) Minimum Gas Pipe Gas Pipe Cap Sediment Trap Suppply Pressure Tap Figure 17 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 38: Gas Supply Pipe Sizing And Looping

    IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers connected to single gas service. Other gas using appliances should be connected upstream from loop. Figure 18 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 39 “National Fuel Gas Code,” ANSI Z223.1/NFPA 54 in the U.S.A., with CSA-B149.1 or Natural Gas and Propane Installation Code in Canada, ● and Australian Gas Association/Australian L.P. Gas Association requirements in Australia. ● Table 4 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 40: High Altitude Burner Orifice Sizing

    0.0890 M406184 180,600 6001-8000 1831-2440 0.0860 M401011 163,400 8001-10,000 2441-3050 0.0820 M401027 146,200 * Btu/hr. derate of 4% per 1000 feet (305 meters) of altitude. Table 5 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 41: Electrical Requirements

    Code, or local codes. Electrical work should be DOES NOT remove all electrical power from done by a qualified electrician. machine. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 42: Service/Ground Location

    Accessory Box NOTE: Do not make service connections in junction box. Power Disconnect Ground Gas or Steam Screw TMB1275N Power Disconnect Electric Ground Screw TMB2125N Figure 19 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 43: To Connect Electrical Service To The Tumbler

    50 and 75 Pound models and counterclockwise on F75 models. b. Disconnect and reverse any two service leads on the terminal block. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 44 Ground Screw (Gas and Steam Models Only) Electrical Service (Electric Models) Ground Buss Bar Accessory Box Contactor Box Ground Lug Disconnect Switch Fuses (Location may vary) Figure 20 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 45: Jumper Configuration Instructions

    T225S Ferrite Ring Contactor Box Jumper Figure 21 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 46: Pound Gas And Steam Models

    L1, L2, L3 and ground 10A – 3 pole 14 (2.08) 440V/60Hz/3ph L1, L2, L3 and ground 10A – 3 pole 14 (2.08) 460-480V/60Hz/3ph N/A = Not Applicable Table 6 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 47: Pound Gas And Steam Models

    L1, L2, L3 and ground 15A – 3 pole 14 (2.08) 240V/60Hz/3ph L1, L2, L3 and ground 10A – 3 pole 14 (2.08) 460-480V/60Hz/3ph N/A = Not Applicable Table 8 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 48: And 75 Pound Electric Models

    400-415V/50Hz/3ph L1, L2, L3 and ground 51A – 3 pole 6 (13.3) 440V/60Hz/3ph L1, L2, L3 and ground 50A – 3 pole 6 (13.3) 480V/60Hz/3ph Table 9 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 49: Steam Requirements

    Connect the steam solenoid valve to the related ● steam coil inlet connection with nipples, flex hoses, unions and tees. Strainers may require cleaning due to materials ● from hoses or pipes. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 50: Piping Recommendations

    4. Install a shut-off valve to each steam trap. 5. Connect to the condensate return lines. 6. For steam solenoid valve wiring connections, refer to Wiring Diagram supplied with tumbler. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 51 Figure 22 Steam Trap Size* Steam Pressure PSI (bar) Minimum Pipe Diameter (Pounds Condensate/Hour) 80 – 100 (5.3-6.9) 3/4 in. NPT *Based on 100 psi. Table 10 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 52: Single Drop Timer

    ON position. All other into READY Mode. dipswitches must be in OFF position. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 53: Dipswitch Settings

    Heat Switch Number Switch Number Cool Down Per Cycle (in Minutes) Heat Time Per Coin Pulse (in Minutes) 1 (factory default) 8 (factory default) Table 11 (Continued) M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 54 Single Drop Timer Table 12 (Continued) Heat Switch Number Heat Time Per Coin Pulse (in Minutes) Total Cycle Time = Heat Time + Cool Down Time M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 55: Rotary Coin Drop Timer

    Meter must be advanced electrically for one cycle before an accurate measure of time can be made. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 56: Adjustments

    3. To adjust the air shutter, loosen air inlet shutter T457I adjusting screw. Air Shutter Adjusting Screws 4. Open or close air shutter as necessary to obtain proper flame intensity. Figure 24 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 57: Airflow Switch

    Retest by opening lint panel and continue moving counterweight away from disc until switch operates as described in step 3. IMPORTANT: Remove tape from lint panel switch. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 58 Adjustments T041I T041I Airflow Switch Switch Lever Mounting Bracket Spring Clip Rear Panel of Tumbler Counterweight Switch Mounting Screws Disc Screw Vane Lever Arm Figure 25 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 59: Loading Door Switch

    Acorn Nut 6. Once proper belt tension is reached, retighten the adjusting nut and locking bolt. Figure 26 7. Replace the guard on rear of tumbler. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 60 Adjustments TMB816N NONREVERSING MODELS TMB816N Poly V-Belt (Self-Adjusting) Drive V-Belt Idler Housing Bolts (2) Idler Housing Assembly Adjusting Bolt Figure 27 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 61 Adjustments TMB817N REVERSING MODELS TMB817N Locking Bolt Guide Rail Adjusting Nut Idler Housing Bolts (2) Adjusting Screw Adjusting Bolt (Not shown) Cylinder Belts Drive Belt Figure 28 M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...
  • Page 62: Removing Tumbler From Service

    Turn off gas supply external to machine. ● Turn off manual gas shut-off valve on machine. ● Turn off steam supply external to machine. ● Remove all electric, gas and steam connections. ● M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT...