[Parameter setting]
f401
f402 Automatic torque boost value
f405 Motor rated capacity
f415
f416
f417
f459 Load inertia moment ratio
thr
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
Setting procedure Adjust the following parameters:
f401 : Set the compensation gain for the slipping of the motor. A higher slip frequency reduces motor
6
f402 : Adjust the primary resistive component of the motor. Decreases in torque due to a possible voltage
f405 : Set the motor's rated capacity according to the motor's name plate or test report.
f415 : Set the rated current of the motor. For the rated current, see the motor's nameplate or test report.
f416 : Set the ratio of the no-load current of the motor to the rated current. Enter the value in % that is
f417 : Set the rated rotational speed of the motor. For the rated current, see the motor's nameplate or test
Adjustment method for the moment of inertia of the load
f459 : Adjusts the excess response speed. A larger value gives a smaller overshoot at the
thr : If the rated capacity of the motor is one size smaller than that of the inverter, lower the thermal
Caution:
Title
Function
Slip frequency gain
Motor rated current
Motor no-load current
Motor rated speed
Motor electronic thermal
protection level 1
slipping correspondingly. After setting f417 , set f401 to adjust in detail. Be careful as
inputting a value larger than necessary causes hunting and other unstable operation.
drop during low-speed operation can be suppressed by setting a large value in this parameter. Be
careful as setting a value larger than necessary may lead to an increased current causing a trip at
low speeds. (Perform adjustments according to the actual operation.)
obtained by dividing the no-load current specified in the motor's test report by the rated current.
Increasing this value increases the excitation current.
report.
acceleration/deceleration completion point. In the default settings, the moment of inertia of the load
(including the motor shaft) value is optimally set considering a motor shaft of 1x. When the
moment of inertia of the load is not 1x, set a value that matches that actual moment of inertia of
the load.
protective level according to the rated c urrent of the motor.
* Sensorless vector control may not operate properly if the motor capacity differs from the
applicable rated capacity of the inverter by more than two grades.
If a combination of the inverter rating and the motor capacity is different for more than 2 classes,
vector control may not operate correctly.
Adjustment range
0-150 (% )
0.1-30.0 (%)
0.01-22.00 (kW)
0.1-100.0 (A)
10-90 (%)
-1
100-64000 (min
)
0.1-100.0 (times)
10-100 (%) / (A)
F-66
E6581697
Default setting
50
Depends on
the capacity
(Refer to
section 11.4)
*1
1.0
100