Fail Over Protection

If the primary management module fails, the redundant management module
will reboot the switch fabric module and interface modules. During this time,
service is affected.
To perform a controlled shutdown on a management or fabric module and
cause the redundant module to take over, enter the following command:
You can also perform a controlled shutdown on a module, by entering the
following command:
To display a list of the slot numbers of all installed modules, type ? after the
N o t e
command; for example, halt ? or power down ?.
Interface modules do not have redundant protection. If an interface
module fails, traffic on the module will stop until you can replace the
module.
Switch 8100fl(config)#halt <slot>
Switch 8100fl(config)#power down <slot>
Replacing Hardware
Replacing Modules