4.1.3 Operation

PROBLEM
When using the speaker-
phone on an APT, nothing
is audible.
When using the speaker-
phone/monitor mode with
a DPT, nothing is audible.
The PT does not ring.
During a power failure,
extensions connected to
ports 1 and 2 of Super Hy-
brid Ports do not operate.
Originating an outside
call, call transfer, or con-
ference cannot be per-
formed.
The LED of the CS does
not change to Green ON.
The LED of the CS stays
Red ON during normal
operation.
"CLEAR SCAN DATA" is
displayed on the PS's
screen after turning on the
PS.
PROBABLE CAUSE
The HANDSET/HEAD-
SET selector is set to the
"HEADSET" position.
The "HEADSET" mode is
selected by Personal Pro-
gramming, "Handset/
Headset Selection".
The ringer volume is off.
A DPT or APT is connec-
ted to the extension port.
The dialling mode (tone or
pulse) is incorrect.
The corresponding CO
button does not exist on
the PT.
CS is not connected prop-
erly.
CS is not set for normal
operation.
The status of the port that
the CS is connected to is
Out of Service.
<KX-TDA0158 only>
Both KX-TDA0158 and
KX-TDA0155 CSs are
connected to the same
card, and the
KX-TDA0158 CSs are
connected to higher-num-
bered pins on the card
than the KX-TDA0155
CSs.
CS malfunction
The PS cannot be used
for normal operation
when scan data is stored
on the PS.
SOLUTION
When the headset is not used, set the
HANDSET/HEADSET selector to the
"HANDSET" position.
When the headset is not used, select the
"HANDSET" mode by Personal Program-
ming.
Turn on the ringer volume.
Disconnect the DPT or APT and connect
an SLT.
Set the Tone/Pulse switch to the other po-
sition.
Programme the CO button. Refer
to "1.20.2 Flexible Buttons" in the Feature
Guide.
Make sure that the cable is connected
properly with correct pin assignments. Al-
so, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Change the port status from Out of Serv-
ice to In Service using the Maintenance
Console.
Connect the KX-TDA0158 CSs to low-
er-numbered pins on the card than the
KX-TDA0155 CSs.
Connect the KX-TDA0158 and
KX-TDA0155 CSs to different cards.
Replace the CS.
Clear the scan data (refer to "2.7.5 Site
Survey Using the KX-TCA255/
KX-TCA256/KX-TCA355/
KX-TD7590" or "2.9.5 Site Survey").