7. Wait five minutes to clear out any gas. Then smell
for gas, including near the floor as some types of gas
are heavier than air.
8. If you smell gas following the five minute waiting pe-
riod in step 7, immediately follow the instructions on
the cover of this manual. If you do not smell gas after
five minutes, move the furnace's gas valve ON/OFF
switch to the ON position.
9. Replace the burner compartment door.
10. Open the external manual gas shut-off valve.
11. Turn on the electrical power to the furnace.
12. Adjust the thermostat to a setting above room tem-
perature.
13. After the burners are lit, set the thermostat to desired
temperature.
Gas Valve
On/Off
Selector
Switch
O
F
F
INLET
ON
Pressure Regulator
Inlet Pressure Tap
Adjustment
(Side of Valve)
(Under Cap Screw)
White-Rodgers
Model 36E22 or 36E23
(View Is Upside Down For Clarity)
Operating Your Furnace
M
1
P
3
C
2
OUTLET
Outlet (Manifold)
Pressure Tap
(Side of Valve)

Shutting Down Your Furnace

To shut down your furnace into operation, follow the
steps listed below.
1. Set the thermostat to the lowest setting.
2. Integrated control closes gas valve extinguishing
flame.
3. Induced draft blower is de-energized following a 15
second delay. The circulator blower is de-energized
following a 60, 90, 120, or 180 second delay period.
4. Remove the burner compartment door.
5. Move the furnace's gas valve ON/OFF switch to the
OFF position.
6. Close the external manual gas shut-off valve.
7. Replace the burner compartment door.